Starting up

 

 

As already mentioned, the R-DT-USB-CW-KBW-101 / R-DT-UHF-CW-RS232-101  is a plug and play reader that can 
be moved anywhere and connected to any computer to be able to use it to scan textiles. 

To prepare it, follow the below steps: 

1.

 

Remove the reader from the box; 

2.

 

Take the USB cable; 

3.

 

Connect the USB cable to the reader; 

4.

 

Place the metal plate to secure the cable; 

 
5.

 

Fix the metal plate with the two screws. 

 

6.

 

Place  the  reader  on  a  non-metallic  desk/table  and  if  needed  secure  it  using  the  mounting  brackets 
included into the box. 

 

Содержание DATAMARS R-DT-UHF-CW-KBW-101

Страница 1: ...www textile datamars com textile id datamars com All in one stationary UHF reader R DT UHF CW KBW 101 R DT UHF CW RS232 101 USER MANUAL Version 2 0...

Страница 2: ...3 Rev 2 0 08 Jun 2022 Table of contents 1 Introduction 3 2 Starting up 4 3 Adjustable parameters 5 3 1 R DT USB CW KBW 101 5 3 2 R DT USB CW RS232 101 7 4 Ho to configure the parameters 9 4 1 R DT USB...

Страница 3: ...to install and configure It is available in two versions one allows to send data to the terminal in keyboard wedge HID and the other in serial mode COM port and thanks to several configurable paramete...

Страница 4: ...d anywhere and connected to any computer to be able to use it to scan textiles To prepare it follow the below steps 1 Remove the reader from the box 2 Take the USB cable 3 Connect the USB cable to the...

Страница 5: ...ix String after the EPC Not defined Output_speed N A N A EPC_format EPC output format for BT communication 1 Uppercase 1 Mode allows to select the operating mode a 1 USB HID keyboard wedge b 3 BT HID...

Страница 6: ...t allows to specify the format of the output string for BT HID connection lowercase or uppercase Examples Length Pointer Prefix Suffix PC RSSI Data String 0 0 0 0 300ED89F3350008CCD2CAC01 0 0 1 0 PCva...

Страница 7: ...1 Mode defines the operating mode 4 serial communication Virtual COM 2 Power set the transmission power from 5 to 30dB 3 Buzzer enable or disable the buzzer 4 PC allows to include the PC into the dat...

Страница 8: ...PC RSSI Data String 0 0 0 0 300ED89F3350008CCD2CAC01 0 0 1 0 PCvalue 300ED89F3350008CCD2CAC01 0 0 0 1 300ED89F3350008CCD2CAC01 RSSIvalue 0 0 Prefix 0 0 Prefix 300ED89F3350008CCD2CAC01 0 0 Suffix 0 0 3...

Страница 9: ...example made with the buzzer parameter 1 Unzip the R DT UHF CW KBW 101 ConfigTool folder on your desktop 2 Keep all the documents inside the same folder 3 Launch the UHFapp exe 4 In the top left corn...

Страница 10: ...been stored and then confirm by clicking on Set 9 Confirm again by clicking on OK and close the window 10 Click on Close to close the connection with the reader and then close the UHFapp 11 Unplug the...

Страница 11: ...eter 1 Unzip the R DT UHF CW RS232 101 ConfigTool folder on your desktop 2 Keep all the documents inside the same folder 3 Launch the UHFapp exe 4 In the top left corner select SerialPort and chose th...

Страница 12: ...been stored and then confirm by clicking on Set 9 Confirm again by clicking on OK and close the window 10 Click on Close to close the connection with the reader and then close the UHFapp 11 Unplug the...

Страница 13: ...reader shall be installed on a non metallic desk table Handling and operation Handle and operate the reader with care significant shocks may damage it Do not place any heavy load on the top of the re...

Отзывы: