background image

P.B.No. 5303, 
Mettupalayam Road, 
Coimbatore - 641 029, India 

1800-102-8888 
www.taropumps.com 
[email protected]

OMOW002A

2020.01

Содержание Taro Pumps SSM Series

Страница 1: ...Single Phase Openwell Submersible Monoblocks Instruction Operating Manual OMOW002A 2020 01...

Страница 2: ...OMOW002A 2 2020 01...

Страница 3: ...t your pump 6 Schematic drawings 7 Key product specifications features 8 Cross section view 9 Pre installation requirements 10 Installation procedures 11 Basic troubleshooting 12 Preventive maintenanc...

Страница 4: ...ou have purchased will be operated correctly This manual is intended to provide you with information on your product and information on installation and operation You will also find information on how...

Страница 5: ...and components using state of the art manufacturing facilities and will give trouble free performance if properly installed and maintained These are compact pumping systems with the pump and motor mo...

Страница 6: ...6 Schematic drawing View of an Single Phase Openwell Submersible Monoblock is shown below in Fig 1 Fig 1 View of Single Phase Openwell Submersible Monoblock OMOW002A 6 2020 01...

Страница 7: ...re 330 C Impeller Type Radial Key features Wide voltage band operation The motor houses water lubricated journal bearings to take up the radial loads A water lubricated thrust bearing is provided to t...

Страница 8: ...d to be dynamically balanced The delivery pipe engages with the mating thread provided on the delivery chamber of the SVSM Strainer assembly fitted on the pump suction flange of TSSM and SSM products...

Страница 9: ...r With Shaft 10 Stud 11 Thrust Pad No PART NAME 12 Csk Head Hex Socket Set Screw 13 Support Rear Cover 14 Rear Cover 15 Diaphragm 16 Diaphragm Cap 17 Hexagon Head Bolt 18 Pvc Insulated Cable 19 Cable...

Страница 10: ...E 15 Hex Head Bolt Washer 16 Stator Stack 17 Hex Head Bolt Nut 18 Hex Socket Set Screw 19 CT BG Collar 20 Base Plate 21 Thrust Bush 22 Rear Cover 23 Cable Gland 24 PVC Insulated Cable 25 Cable Gland B...

Страница 11: ...Sand Guard 9 Strainer 10 Suction Chamber 11 Earth Screw No PART NAME 12 Washer 13 Cable Gland 14 Stud 15 Sleeve 16 Lock Pin 17 Bush 18 Cable Clamp 19 Cable Protector 20 Cable 21 Delivery Chamber 22 He...

Страница 12: ...completely filled with water Top up if required with pure drinking water It is recommended to assemble the Single Phase Openwell submersible on a fairly level base to prevent the pump and piping from...

Страница 13: ...se trained professionals to install the Single Phase Openwell Submersible Warning Use a power supply cable that has sufficient rating Factor in low voltage operation Warning Provide proper Earthing Im...

Страница 14: ...sible has water lubricated journal and thrust bearings and therefore shall not be run dry Starting of the Single Phase Openwell Submersible without water must be strictly avoided as it will cause dama...

Страница 15: ...e Single Phase Openwell Submersible monoblock The following steps are executed prior to installation Installation Open the filling plugs and top up if necessary the motor with pure drinking water Meas...

Страница 16: ...two plugs Fig 6 Filling the motor of single phase openwell submersible monoblock with pure drinking water Prior to installation unscrew the Brass Plugs 1 and 2 fitted on top of the motor as shown in F...

Страница 17: ...ly assemble the pump stand in the delivery flange as shown in pictures d e and f and tighten the screws Fig 8 Assembly procedure Pump stand Both Motor Pump Stands should be assembled opposite to the c...

Страница 18: ...ntally switched ON Standard Single Phase Openwell Submersible are supplied with a 3 core PVC insulated flat cable of length 3 meters On demand a 10 m long cable can be supplied The free end of the 3 c...

Страница 19: ...knot the copper strands Step 6 Layer 1 1st layer of virgin rubber insulation Step 7 Layer 2 1st layer of PVC insulation tape Step 8 Layer 3 2nd layer of PVC insulation tape Step 2 Layer 1 1st layer o...

Страница 20: ...23 484 837 9 5 1 1 1 5 75 126 204 306 529 835 13 1 5 2 55 92 149 223 386 610 946 20 2 2 3 60 96 145 251 396 615 866 28 3 7 5 69 103 179 283 439 618 888 Refer TABLE 2 for the selection of cables from C...

Страница 21: ...ler from whom the purchase was made for rectification Electrical Installation Check the power supply voltage and frequency and compare with the product requirements specified on the nameplate Observe...

Страница 22: ...g 10 Earth Connections SSM and SVSM Fig 10 a Fig 10 b EARTH SCREW DIRECTION OF ROTATION FILLING DRAIN PLUG EARTH SCREW Warning Be sure to install the ground wire securely Failure to observe this preca...

Страница 23: ...he wires to the terminal board make sure the power supply is properly disconnected Failure to do so may lead to electrical shock short or injury caused by the unintended starting of the pump Caution D...

Страница 24: ...trips again check the voltage Pump is jammed Dismantle the pump and clear the jammed parts Fuse has blown Replace fuse Loose connections Tighten the electrical connections Pump has been kept idle for...

Страница 25: ...o low Abrasive wear of pump hydraulics due to operation in water of higher sand content or corrosiveness Change the worn out pump parts Running at low voltage Wait for voltage to increase or contact l...

Страница 26: ...ified troubles of Single Phase OWS as it may lead to severe damage to the pump or injury to personnel Contact the dealer from whom this pump was purchased Caution If the Single Phase Openwell Submersi...

Страница 27: ...OMOW002A 27 2020 01...

Страница 28: ...inspections should be established to avoid breakdown serious damage and or extensive downtime The schedule will depend on operating conditions and experience with similar equipment The below checklist...

Страница 29: ...should be compared to corresponding data recorded when the unit was initially installed Any reduction in shut off head may indicate wear of the pump hydraulics Any increase in motor current at duty f...

Страница 30: ...delivery head use a check valve in the discharge line Do not use undersized electric cables between Pump and control panel Factor in low voltage usage In case of flooded suction ensure that the pump s...

Страница 31: ...andling installation and maintenance It is suggested that in case of non functioning of the product the customer is requested to contact the dealer through whom the purchase was made Danger Hazardous...

Страница 32: ...f the product has been stored for a very long period check the condition of the rubber gaskets free rotation of the shaft and level of water inside the motor Caution If the pumpset is stored the shaft...

Страница 33: ...16 Company contact information For most up to date information on Texmo Industries please visit www taropumps com OMOW002A 33 2020 01...

Страница 34: ...OMOW002A 34 2020 01...

Страница 35: ...P B No 5303 Mettupalayam Road Coimbatore 641 029 India 1800 102 8888 www taropumps com info taropumps com OMOW002A 2020 01...

Отзывы: