Electrical wiring work
Earthing
Warning
All electrical work must be performed by an authorised electrician in compliance with
local electrical equipment standards and internal wiring codes. Improper wiring can
lead to current leakage, electrical shock, or fire.
Warning
Be sure to install the ground wire securely. Failure to observe this
precaution could damage the pump and cause current leakage, which may
lead to electrical shock
Caution
Do not connect the ground wire to a gas pipe, water pipe, lightning rod, or
telephone ground wire. Improper grounding could cause electrical shock
Electrical Installation
Check the power supply voltage and frequency and compare with the product requirements
specified on the nameplate
Observe relevant EB regulations while providing power supply to the motor
As far as possible, do not use multiple joints in the electrical cabling while connecting the starter
to the pump
Ground the pump using the two earth screws provided on the leg of the motor body
Ensure electrical joints, if any, are properly and adequately insulated
Connect the cable properly to the starter terminals to avoid loose connections
Factor in low-voltage operation while selecting cable size