background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

UM-35-SG manual (UM09)

Page 1

General Features

Specifications

Typical Application Connections

IS05 

: Pressure/Load Cell 

2

/20mV/V, 5/

10V

 Exc 4-wire

+Exc

Input Lo

_Exc

Input Hi

PRESSURE TRANSDUCER

Input Configuration:

 ��������Differential 

Full Scale Ranges:

 ����������Accepts inputs from 2mV/V or 20mV/V 

trans duc ers

Excitation �������������������������

5V or  10V DC� Ratiometrically 
compensated to operate with all transducer 
output ranges�

A/D Converter:

 �����������������12 Bit Dual Slope

Accuracy:

 �������������������������±(0�05% of r 2 counts)

Temperature Coefficient:

 100 ppm/°C (Typical)

Warm Up Time:

 ����������������2 minutes to specified accuracy

Conversion Rate:

 �������������3 conversions per second (Typical)

Display:

�����������������������������3 1/2 digit 0�56" Red LED display (std), 

Green or Super Bright Red are optional� 

Range 0 to 1999 counts� 

Decimal Selection:

 ����������

Header under face plate, X•X•X•X•

Over-range Indication:

 ����1 (MSD) displayed all other digits blank

Power Supply (std):

 ���������120/240V AC, 50/60/400 Hz� approx 1�5W�

(Optn) VO-DC/ISO ����������Isolated Switcher� 9 to 36V DC/12 to 24V AC

Operating Temperature:

 ��–10 to 50 °C

Storage Temperature:

 �����–20 to 70 °C�

Relative Humidity:

 �����������95% (non-condensing)

Case Dimensions:

 �����������Bezel 3�78”Wx1�89”H (96mm x 48mm) 

Depth behind bezel 3�36" (83�5mm) Plus 

0�5 to �9” (12�7 to 22�8mm) depending on 

connector used�

Weight:

 �����������������������������NW� 12oz (0�34kg)

                                       15�6oz (0�44kg)� when packed�

UM-35-SG

Pressure or Load Cell Meter

3 1/2 DIGIT with 0.56” LEDs

in a NEMA type 1 Style Case

An cost-effective meter to measure 4 wire pressure 

transducers, strain gauges and load cells. . 

The UM-35-SG has two header selectable trans duc er output 

ranges of 2mV/V and 20mV/V� Both ranges can provide a full 

scale display of 2000 counts from the precision ratiometrically 

compensated 5V or 10V DC excitation provided by the meter� 

The meter accepts 4 Wire, and like all UM-Series meters, is 

easily scaled to display in en gi neer ing units such as psi, bar, 

kbar, kpa, feet, lbs, and tons� 

UM-Series

Optional super 

bright LEDs

UM-Series utility meters for switchboard and process indication

UM-35-ACA

 ....AC amps, Scaled or True RMS, (

1 or 5 Amp

 internal shunt), 3.5 digit.

UM-35-ACV

 ......AC volts, Scaled or True RMS. 

199.9V AC

/700V AC header selectable ranges,  

                            3.5 digit.

UM-35-DCA 

 ....DC mV ±20mV/

±50mV

/

 

±100mV/

±200mV header selectable ranges, 3.5 digit

UM-35-DCV

 .....DC Volts 

±2V

/±20V/±200V DC header selectable ranges, 3.5 digit.

UM-40-ACA

 ....AC amps, Scaled or True RMS, (

1 or 5 Amp

 internal shunt), 4.0 digit.

UM-40-ACV

 ....AC volts, Scaled or True RMS. 

199.9V AC

/700V AC header selectable ranges,

                            4.0 digit.

UM-45-DCA

 .....DC mV ±20mV/

±50mV

/

 

±100mV/

±200mV header selectable ranges, 4.5 digit

UM-45-DCV

 ....DC Volts 

±2V

/±20V/±200V DC Header selectable ranges, 4.5 digit.

UM-35-CL

 .......Process 4 to 20mA 

(100.0)

, easily user scalable in engineering units from 

                         –1999 to +1999. 3.5 digit

UM-35-HZ

 .......

15Hz 

to

 199.9Hz

 or optional 40Hz to 400Hz up to 500V AC , 3.5 digit.

UM-35-Pressure

..Pressure, strain gage and load cell, 4 and 6 wire, 5V DC excitation,

 

Header Selectable Sensitivity 2mV/V, 5mV/V, 10mV/V, 

20mV/V

, 3.5 digit

UM-35-JF

 ........

J

 thermocouple input, 1° resolution, order 

°C

 or 

°F

, 3.5 digit

UM-35-KF

 .......

K

 thermocouple input, 1° resolution, order 

°C

 or 

°F

, 3.5 digit

UM-35-RTD/F

 ..100Ω platinum RTD, 3 or 4 wire, order 

°C

 or 

°F 

and 

0.1°

 or 

, 3.5 digit

UM-45-CL

 .......Process 4 to 20mA 

(100.0)

, easily user scalable in engineering units from 

                         –19999 to +19999. 4.5 digit

Low Range Adjustment : 0-1000 counts

Hi Range Adjustment : 1001-1999 counts

Отзывы: