background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 1

DX-35_UL DS (DX1_UL)

LYNX

LYNX FAMILY

• 

Pre-calibrated 

I-Series

 Input Signal Conditioning 

modules, that have span or zero potentiometers, can be 

interchanged between any 

I-Series

 compatible meter, 

without recalibration, because all of the analog scaling and 

reference circuitry is self-contained within the module.

• 

24 V DC excitation is available to power external 

transmitters and 5 or 10 V DC excitation is available for 

strain-gages, load cells and resistance bridge type sensors.

• 

AC/DC Auto-sensing power supply. For voltages between  

85-265 V AC / 95-300 V DC (PS1)

 or 15-48 V AC / 10-72 V DC (PS2).

• 

Standard red or optional green or super bright red 3 1/2-digit 

0.56” LED with display range –1999 to 1999 (4000 counts).

•  Red or green 0.8" LED large display option.
•  Display brightness may be externally controlled.
•  1/8 DIN (96 x 48mm ) case easily mounts in thin or thick 

panels (up to 2’). May be ordered with optional extra fire 

resistant metal case.

•  Optional NEMA-4X, IP-65 hinged, lockable, water and dust 

 

proof cover.

• 

UL Listed

A versatile digital panel meter with standard or large 

display, for monitoring and measurement applications.

DX-35

Lynx Panel Meter

3 1/2 DIGIT 0.56” or 0.8” LED

in a 1/8 DIN Case

General Features

Specifications

Input Module Compatibility

Input Specs

: ..............Depends on input signal conditioner 

A/D Converter

: ..........12 bit dual slope

Accuracy

: ..................±(0.05% of r 2 counts)

Temp. Coeff

.: .............100 ppm/°C (Typical)

Warm up time

: ...........2 minutes

Conversion Rate

: ......3 conversions per second (Typical)

Display

: ......................

3 1/2 digit 0.56" Red LED display (std)

0.56” or 0.8” Green or Super Bright  

Red (optn). Range –1999 to 1999 counts. 

Polarity

: .....................Assumed positive. Displays – negative

Decimal Selection

: ....

Header under face plate, X•X•X•X

Positive Overrange

: ..

1 (MSD) is displayed with all other 

digits blank.

Negative Overrange

1 (MSD) and – sign are displayed with 

all other digits blank.

Power Supply

: ...........AC/DC Auto sensing wide range supply

 

PS1 (std)

 ................

85-265 VAC, 50-400Hz / 95-300 VDC @1.5W 

 PS2 .........................15-48 VAC,50-400Hz / 10-72 VDC @4.0W 

Operating Temp

.: ......0 to 50 °C

Storage Temp

: ...........–20 °C to 70 °C.  

Relative Humidity

: ....95% (non condensing)

Case Dimensions

: ....

1/8 DIN, Bezel: 96x48 mm (3.78"x1.89")

 

Depth behind bezel: 117 mm (4.61")

 

Plus 11.8 mm (0.47") for Right-angled 

connector or plus 20 mm (0.79") for 

Straight-thru connector.

Weight

: .......................

8 oz., 11 oz when packed. 

Case Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Component Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Connector Pinouts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Functional Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

I-Series Input Signal Conditioning Modules

. . . . . . . . . . . . 3-5

Input Module Calibration Procedures

. . . . . . . . . . . . . . . . . 6-7

Input Module Compatibility

. . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Input Module Component Glossary

  . . . . . . . . . . . . . . . . . . . . 6

Installation Guidelines  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Ordering Information

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Index

 LYNX FAMILY

:  

More than 33 different Plug-in 

 

I-Series

 Input Signal Conditioners are approved 

for Texmate’s Lynx Family of meters. As shown on 

pages 3 to 5. 
See www.texmate.com for an up to date listing.

  – AC Current 

  – AC Voltage 

  – DC Current 

  – DC Voltage

  – Load Cell

  – Pressure

  – Process

  – Prototype 

  – Resistance

  – Strain-gage

 –Temperature 

  – 4 to 20 mA

 Large display option 

0.8” red or green LED

•  External transmitters or signal conditioners can be eliminated  by 

directly connecting the sensor to more than 33 

I-Series

 Plug-in 

Input Signal Conditioners that include: 

E469078

Содержание DX-35-XX-PS1

Страница 1: ...second Typical Display 3 1 2 digit 0 56 Red LED display std 0 56 or 0 8 Green or Super Bright Red optn Range 1999 to 1999 counts Polarity Assumed positive Displays negative Decimal Selection Header un...

Страница 2: ...to this Common Pin Pin 12 Dim Blank When this pin is connected to the Common Pin 11 the display is blanked out If it is connected through an external 1K pot the display may be dimmed Pin 14 15 AC DC P...

Страница 3: ...C AC Amps Scaled RMS 1 Amp AC IA05 AC AC Amps Scaled RMS 5 Amp AC Many additional input modules are available and others are constantly being developed Check with your local distributor or www texmate...

Страница 4: ...00V 20V 2V ON OFF 24V Exc 24V Exc Increase Span Decrease LEOPARD IP07 LYNX TIGER IP07 090D 200 100 50 20 ID02 DC Millivolts 20 50 100 200mV DC w 24V DC Exc 24V Exc ON OFF 24V EXC DCmV Increase Span De...

Страница 5: ...x only LEOPARD IR05 187C 4 wire 2 wire 3 wire 4 wire 3 wire IR05 Resistance 2K Leopard only LYNX IR04 IS05 Pressure Load Cell 20 2mV V 5 10V Exc 4 wire Pressure Transducer or Load Cell 2 HI LO RANGE m...

Страница 6: ...for Excitation Voltage output HI LO 24V Exc Offset 0 0 INPUT RANGE Header Range values are marked on the PCB Typically two to four positions are provided which are selected with either a single or mul...

Страница 7: ...t position If the module has a ZERO ADJUST Header select the position that will provide a negative offset of 500 counts Apply 1 V and adjust the ZERO pot until the display reads 100 Apply 5 V and chec...

Страница 8: ...s Shielding cables for input output leads is recommended with shield connection to earth ground near the meter preferred 4 A circuit breaker or disconnect switch is required to disconnect power to the...

Страница 9: ...pecial scaling beyond the std range 40 CSS 34 INSTL Installation specify serial CSS 25 OP DXEXTDP External Dec Pt W Conn Option Factory Installed 20 ACCESSORIES Specify Serial for Custom Artwork Insta...

Отзывы: