Serial Port
The four serial ports can be configured as RS-232, RS-422 or RS-
485 by software. They use RJ45 connector and the pin assign-
ment are shown as following table.
Port 1: RS-232/422/485
RS-232: RXD,TXD,RTS,CTS,DSR,DTR,DCD,GND
RS-422: TXD+, TXD-,RXD+,RXD-,GND
RS-485: DATA+,DATA-,GND
Port 2/3/4:
RS-232: RXD,TXD,RTS,CTS,GND
RS-485: DATA+, DATA-, GND
Serial Console Port: (JP1)
Serial console port is used for locally accessing Matrix-605 sys-
tem using RS-232 port. The console port is located inside the box
and close to battery. It is a four-pin wafer box header. User can
order wafer console cable to access the serial console port.
Port 0: RS-232:RXD,TXD,GND
Therefore you need to open the upper metal case and prepare or
purchase a serial console cable to use the serial console port .
Power Connector
Connect the 9 to 48VDC power line to Matrix 605. If the
power is properly supply.
Ethernet Port
The Ethernet Ports use RJ45 connector
+
-
Initial Table:
WinCE uses initial table to decide the order of program/
service to start after power on. You can use
init
command to
configure the initial table as follow:
Number 70 is Artila Manager and Number 71 is WinCE re-
mote display control.
Power on and System boot up
Once Matrix-605 is correctly power on, you can see the mes-
sage prompt from the serial console port. The system starts
from the initial table and a batch file,
autoexec.bat
which is
located at \NandFlash will follow up. Therefore user can edit
the
autoexec.bat
file or init table for your auto run program.
To skip the autoexec.bat, please repeatedly key $ (shift+4)
right after system boot up.
Factory Default Settings
LAN 1:
IP setting: DHCP
LAN 2:
IP Address: 192.168.2.127
Serial Console Port:
Baud rate: 115200
Data format: 8 Bits, No Parity, 1 Stop bit (N,8,1)
Flow Control: None
Terminal type: VT100
Serial Console
TxD
RxD
VCC3
GND
1
2
3
4