background image

Remote Keypad

I N S T A L L A T I O N   M A N U A L

THANK YOU FOR VOTING TEXECOM

THANK YOU FOR VOTING TEXECOM

THANK YOU FOR VOTING TEXECOM

THANK YOU FOR VOTING TEXECOM

Содержание Veritas RKP

Страница 1: ...Remote Keypad I N S T A L L A T I O N M A N U A L THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM...

Страница 2: ...at the base of the unit Gently twist the screwdriver to ease the retaining clip upwards Do NOT use excessive force The front and flap can now be removed The PCB assembly is hinged for easy access Alte...

Страница 3: ...series daisy chain ensure that the voltage at the keypad is not more than 2V less than the voltage at the control panel 2 When using 6 core or 8 core cable always use the spare cores to double up on...

Страница 4: ...T and R not connected the zone LED corresponding to the address currently selected will light 4 If an invalid address is selected the keypad will sound an error tone 1 4 Programming When the system i...

Страница 5: ...KPs option 4 Press PROG the system will chime scan for RKP addresses 1 6 5 Press RESET to revert to the Programming Menu 6 Press RESET to revert to the unset state 1 If a keypad is not configured it w...

Страница 6: ...600mcd typical Cable 4 Core 100m Connection Serial Parallel or any combination 1 2 Environmental Operating Temperature 10 C 14 F to 50 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humid...

Страница 7: ...on Quality is carefully monitored by extensive computerised testing As a result the Veritas RKP is covered by a two year warranty against defects in material or workmanship details on request As the V...

Страница 8: ...Cable entry MUST use either the top left hand hole or the cable channel NEVER run cables behind the PCB Figure 1 Cable Entry INS 037 5...

Отзывы: