background image

 16 

DETECTOR KNOCKOUTS

   

 18 

WALL MOUNT BRACKET

 15 

HOW TO REMOVE THE CHASSIS 

   

Remove chassis before mounting the detector

 

 14 

CHOOSING A LOCATION 

 

   

Avoid common false alarm sources

 13 

WIRING 

 

 

 

 

        

Do not run cable parallel to mains wiring

 12 

MOUNTING THE PRESTIGE DT 

   

Mount on a stable surface

 

 11 

MOUNTING THE PRESTIGE DT 

   

For indoor use only

 10

 

COVERAGE PATTERN 

   

Volumetric

  9

 

CONFIGURING SENSITIVITY &  

   

TESTING

2

2

4

1

3

1

3

4

5

7

5

8

Seal all holes

INS 

332

See Mounting Height Diagram (Section 7)

6

 17 

CEILING MOUNT BRACKET

<3'3"/1m

50

15m

50

15m

90º

Select the appropriate pulse count and microwave range for the intended installation with JP1 
and VR1 and enable the LEDs with JP2.  Replace the cover, apply power to the detector and 
wait 1 minute for the warm-up period to complete.  
With  the  area  free  of  people,  walk  through  the  desired  protected  area  and  ensure  that  the 
detector  operates  correctly.  Ensure  that  all  the  detector  LEDs  illuminate  and  that  the  relay 
contacts open to signal an alarm.
As the absolute range of PIR detectors can vary with ambient temperature, background and 
clothing type, ensure that the most likely intruder routes are well within the detectors range 
and walktesting is carried out along these routes. The LEDs may be disabled after testing. 
Ensure changes in the installation environment do not affect the detectors field of view.

110V
230V

110V
230V

 

In North America the 

Prestige DT

 must be connected to a UL (USA or CSA-Canada) 

approved power supply, current limited to its rated value, capable of providing at 
least 26mA per 

Prestige DT

 at 12V

DC

 nominal (9-16V

DC

 range), and capable of 

providing 4 hours minimum standby power.
Installation in the USA must comply with National Electrical Code, NFPA70.
Installation in Canada must comply with Canadian Electrical Code Part 1.