INS181-5 5/9
1.3 Wiring
It is strongly recommended that the system is completely powered down (mains
and battery) before wiring a keypad. Connect the keypad to the control panel using
4-core cable as follows:
Up to six keypads may be connected in parallel (‘star’) or series (‘daisy‑chain’) or
any combination.
N
When using long cable runs or connecting keypads in series (‘daisy‑chain’)
ensure that the voltage at the keypad is no less than 10.0V. When using 6-core or
8-core cable always use the spare cores to ‘double-up’ on 0V. This will allow longer
cable runs particularly when connecting keypads in series (‘daisy‑chain’). As a rule
‘trebling‑up’ on 0V will be more beneficial than ‘doubling-up’ on 12V and 0V.
Keypad Zones
The Premier RKP8/16 Plus has two fully programmable zone inputs (Z1 COM Z2).
For information on wiring configuration options please refer to the Premier 412/816
Installation Manual.
In order to use the keypad zones, you must first enable the zones using Menu 43
Option 1 (refer to the Premier 412/816 Installation Manual). When a keypad has its
zones enabled they are mapped onto the system as shown: