Premier Elite Com GSM Module Installation Manual
INS315-4
7
Installation
The
Premier Elite Com GSM module should be installed as close to the control panel as possible, so that the
harness lead supplied with the unit is able to plug onto the control panel communication port.
The connection harness cannot be extended.
1.
Route the harness lead into the module housing using the cable entry plate at the top of the unit, and plug
the connector onto COM1 [
2]
2.
Install the module in the required location using suitable fixings.
3.
Route the other end of the harness lead into the control panel housing. DO NOT CONNECT at this point.
4.
Connect the GSM antenna to the antenna connector on the module [
1] and site the antenna as high as
possible.
5.
Unlock the SIM socket by sliding the locking tab downwards. Insert the SIM card into the holder with the
chamfered corner to the top left. Push the holder back into position and lock the SIM by sliding the locking
tab upwards.
The SIM card must be inserted before connecting the Premier Elite ComGSM module to the control
panel, and must not be removed until after the power supply to the Premier Elite ComGSM module
has been deactivated.
6.
Set the option switches as required, see page 6.
7.
Now connect the harness lead onto the control panel communication port (COM 2 for the
Premier 24
;
COM 1 or 2 for the
Premier 48/88/168/640 Premier Elite 24/48/88/168/640& Premier 412/816/816Plus/832
).
The module should now be powered and the heartbeat LED [
5] should be flashing.
You should check and confirm that the signal strength is still the same as recorded during the site
survey.