Premier Elite Com300
&
Com2400
Installation Manual
INS175-5
3
Digimodem Features
•
8 channel multi format digital communicator supporting
Fast Format, Contact ID, SIA
Level 2/3 and EasyCom Pager protocols
•
6 Alarm Receiving Centre telephone numbers (up to 24 digits each)
•
Fully programmable reporting codes (Contact ID & SIA Level only)
•
300-baud modem (
Com300
) or 2400-baud modem (
Com2400
) for uploading and
downloading control panel information over a telephone line using the
Wintex UDL
software and a PC
•
REN = 1
•
Short Message Service (SMS) to mobile phones (
Com2400
ONLY)
Connection Status
The digimodems can accept serially connected telephone apparatus. When the digimodems are
online they will temporarily disconnect all serially connected telephone apparatus (e.g. phones,
answer-phone, etc.) so that they do not interfere with data transmission. This means that the
digimodems do not have to be connected to a dedicated telephone line (see telephone line
connection
NOTES
on page 9).
Connection terminals on the
Com300
and
Com2400
are described as either ‘Safety Extra Low Voltage’ circuits
(SELV) or ‘Telecommunications Network Voltage’ circuits (TNV).
•
It is important that the TNV connections are only connected to the PSTN, and SELV circuits
are only connected to other circuits designated as SELV circuits
•
Interconnection circuits should be such that the equipment continues to comply with the
requirements of 4.2 of EN 41003 for TNV circuits and 2.3 of EN 60950 for SELV circuits, after
making connections between circuits
The digimodem layout shows the two types of circuits.
Premier Series
Control Panel
Alarm Receiving
Centre
Modem
PC and Modem for
Remote Upload/Download
Plug on Digimodem
(ComISDN)