Installation Manual
Premier Elite Com300/Com2400
INS175-5
Страница 1: ...Installation Manual Premier Elite Com300 Com2400 INS175 5 ...
Страница 2: ... successful operation with every PSTN network termination point In the event of problems you should contact Technical Support at Texecom Ltd The Premier Com300 and Com2400 digimodems have both been approved for the following usage Automatic Call Initialisation Automatic Dialling Modem Serial Connection Multiple Repeat Attempts Line Status Monitoring Any other usage will invalidate any approval giv...
Страница 3: ...pparatus e g phones answer phone etc so that they do not interfere with data transmission This means that the digimodems do not have to be connected to a dedicated telephone line see telephone line connection NOTES on page 9 Connection terminals on the Com300 and Com2400 are described as either Safety Extra Low Voltage circuits SELV or Telecommunications Network Voltage circuits TNV It is importan...
Страница 4: ...downloading control panel information you will require a PC with Windows 95 98 NT XP Vista or 7 and an analogue modem that supports V 21 V 22 or V 22bis operation To obtain your copy of the Wintex UDL software please visit our website Communicator Operation When a reportable system event occurs the digimodem will seize the telephone line and dial the telephone number for the Alarm Receiving Centre...
Страница 5: ... Digimodem To install the digimodem proceed as follows 1 Isolate ALL power from the control panel AC Mains and Battery Do not continue if there is power still present on the control panel 2 Installing the digimodem with power still present on the control panel will seriously damage the digimodem and invalidate any warranty 3 Ensure that the board is the correct way up see picture below 4 Locate th...
Страница 6: ...ired cores and feed through the cable entry Alarm or any other type of cable must not be used 4 Connect the cores to the terminal blocks marked T R If required connect serial devices to T1 R1 on digimodem 5 Ensure the the eath terminal on the digimodem is connected to mains earth 6 Remove the two screws from the BT master socket and remove the bottom section from the master socket 7 Connect the ca...
Страница 7: ...setup the Com Ports for the Com300 or Com2400 proceed as follows 1 Enter into the Engineers Menu 2 Select the UDL Digi Options menu and press 3 Select the Com Port Setup menu and press Select Onboard Digicom and press Select Com300 or Com2400 and press 4 If fitting a Com2400 to a Premier 24 only V10 select Com1 and press Select Com2400 and press COM1 will not be available for use by any other devi...
Страница 8: ...the Restoring channels For Fast format select the Open Close channels For all other formats select the Areas that will report events For all other formats select the types of events that will be Reported Select any Config Options that may apply 3 To exit from the Program Digi menu press 4 Select the Digi Options menu and press Select Digi is Enabled Select any other options that may be applicable ...
Страница 9: ...e r T i m e a n d D a te E v e n t Ty p e Z o n e U s e r n a m e te x t A r e a th a t c a u s e d th e e v e n t N a m e p r o g r a m m e d i n to p h o n e Testing the communicator Before attempting to send a test call to the Alarm Receiving Centre ensure that the account is on test Once all the installation steps have been completed proceed as follows 1 Reconnect power to the control panel 2 ...
Страница 10: ...om2400 only Modem Protocol Com300 Com2400 V 21 300 baud V 21 V 22 or V 22bis 300 1200 or 2400 baud Telephone Numbers Up to 6 up to 24 digits each Dialling Formats Pulse DTMF REN 1 0 Approval CTR21 Operating Temperature 10 C 14 F to 55 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humidity 95 non condensing EMC Environment Residential Commercial Light Industrial Industrial Dimensions W...
Страница 11: ...6662 at Grade 2 and Environmental Class II COM300 COM2400 DIGI MODEMS comply with the requirements of EN50136 2 3 EN50136 1 1 and are suitable for use in systems designed for use with ATS levels 1 or 2 and environmental class 1 or 2 ie systems using notification options up to and including 2B With the PSTN functioning normally the ATS will comply with the required performance levels subject to the...
Страница 12: ...shire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1706 233875 Email techsupport texe com Texecom Limited 2011 INS175 5 ...