Programming zone arming and disarming:
(Note that Zone 7 and 8 has been used as an example)
AWAY arming Relay1
Connect relay 1 to Zone 7 with resistor in series to the NC and COM
Go into programming
Go to Zone Setup and press YES
Use the arrow key and go to zone 7. Press NO to edit and use the arrow key to go to
MOMENT KEY and select it by pressing YES
Press YES to go to Attributes 1 and press NO to edit. Use the arrow key to go to INSTANT
ARM and press NO to Enable it and press YES
STAY arming Relay2
Connect relay 2 to Zone 8 with resistor in series to the NC and COM
Go into programming
Go to Zone Setup and press YES
Use the arrow key and go to zone 8. Press NO to edit and use the arrow key to go to
MOMENT KEY and select it by pressing YES
Press YES to go to Attributes 1 and press NO to edit. Use the arrow key to go to PART 1 OMIT
and press NO to Enable it and press YES
To exit and save programming:
Press MENU and the Keypad will ask if you want to exit and log off, Press YES