Texecom Mirage Dual Technology Скачать руководство пользователя страница 1

1

PHYSICAL

4

9

COVERAGE AT 2m

6

COVERAGE & PICK-UP

8

MOUNTING HEIGHT &
SETTINGS

1.5m

(4'10")

2.5m

(8'4")

3.1m

(10'0")

3.6m

(11'9")

4.1m

(13'6")

2.0m

(6'7")

-35°C (-31°F) to +60°C (+140°F)

190g (7oz) approx.

-10°C (14°F) to +55°C (+131°F)

66mm
(2.6

41mm
(1.6

116mm
(4.6

2.5mm (0.1

) ABS

7

ANGLING THE DETECTOR

2

ENVIRONMENTAL

QUALITY ASSURANCE

WARRANTY

5 year replacement warranty.

The 

Mirage Dual Technology

is designed to detect the movement of an 

intruder and activate an alarm control panel. As the 

Mirage Dual Technology 

is not 

a complete alarm system, but only a part thereof, Texecom cannot accept

responsibility or liability for any damages whatsoever based on a claim that the 

Mirage Dual Technology

failed to function correctly.

Due to our policy of continuous improvement Texecom reserves the right

to change specification without prior notice. All specifications are measured at

20˚C (68˚F).

Document Ref: M/EU/2.0-6
© 1994 - 2004 Texecom Ltd

C e r t i f i c a t e   N u m b e r :   F M   3 5 2 8 5

3

FALSE ALARM PROTECTION

Design:

Intelligent 

A

DAPTIVE

S

IGNAL

P

ROCESSING

™ (ASP™)

.

Noise reduction circuits with maximum ground plane.

Electrostatic Discharge:

No false alarm up to 8kV air. Complies with 
IEC 1000-4-2.

RF Immunity:

No false alarm from 150kHz to 1GHz at 10V/m 100%
pulsed modulation. 30V/m 80% sinusoidal modulation.
Complies with IEC 1000-4-3. Equivalent to a 270W
uniform transmitter at 10ft (3m).

Fast Transient Immunity:

No false alarm up to 4kV. Complies with IEC 1000-4-4.

RF Common Mode
Clamp:

No false alarms 150kHz to 80MHz. Complies with 
IEC 1000-4-6.

Conducted Emissions:

Complies with IEC CISPR 22.

Radiated Emissions:

Complies with IEC CISPR 22, FCC Part 15.

EMC:

Independently certified to EN 50130-4 : 1996.

Microwave Range:

Internal pot to adjust.

Approvals:

Complies with: MPT 1349, I-ETS 300 440, FCC Part 15.

Pulse Count:

Internal link to select.

INS 044-6

MIN

MIN MAX

JP1

0.3 - 3.0m/s

A

B

C

D

E

F

G

H

<24V

DC

50mA

(N/C)

<24V

DC

50mA

, 18

(N/C)

9-16V

DC

20mA @ 12V

DC

Latch Input F

unctions

(see Section 5)

R

emote LED:

12V            0V/NC

RL

LA

0V

12V

ALARM

TAMP

MIN

MAX

MIN MAX

MAX

JP1

5

REMOTE LED & LATCH INPUT

FUNCTIONS

The latch terminal (see Section 4) can perform several different functions 

depending on how it is connected: 

Latch connected to Set Positive (SW+, Set+):

The LEDs will be disabled while

the system is set. Any detectors triggered while the system is set will indicate

this by permanently lighting the Alarm LED (upon unsetting the system). 

Detectors can be reset by taking the latch line high and then low again.

Latch connected to Alarm Positive (AL+, A+ve): 

The first detector activated 

while the system is set will indicate this with a slowly flashing Alarm LED 

(upon unsetting the system). Detectors which activated subsequently will 

indicate this by permanently lighting the Alarm LED. Detectors can be 

reset by taking the latch line high and then low again.

The latch input is not suitable for use on entry/exit or walk through zones.

Remote LED: 

Connect RL to12V to disable the walk test LEDs.

Connect RL to 0V or leave unconnected to enable the walk test LEDs.

MW

ALARM

PIR

PULSE COUNT

2

1

LED OFF

LED ON

IMPORTANT

Ensure Microwave Range is set at correct level for

desired coverage

MIN MAX

JP1

1 - 10ft/s

Dual Technology Microwave & Infrared Detector

I N S TA L L AT I O N   I N S T R U C T I O N S

www.texe.com

T H A N K   Y O U   F O R   V O T I N G   T E X E C O M

Ask your distributor today for the new Texecom full colour Product Guide.

W I N N E R

Отзывы: