1
PHYSICAL
4
9
COVERAGE AT 2m
6
COVERAGE & PICK-UP
8
MOUNTING HEIGHT &
SETTINGS
1.5m
(4'10")
2.5m
(8'4")
3.1m
(10'0")
3.6m
(11'9")
4.1m
(13'6")
2.0m
(6'7")
-35°C (-31°F) to +60°C (+140°F)
190g (7oz) approx.
-10°C (14°F) to +55°C (+131°F)
66mm
(2.6
”
)
41mm
(1.6
”
)
116mm
(4.6
”
)
2.5mm (0.1
”
) ABS
✓
7
ANGLING THE DETECTOR
2
ENVIRONMENTAL
QUALITY ASSURANCE
WARRANTY
5 year replacement warranty.
The
Mirage Dual Technology
is designed to detect the movement of an
intruder and activate an alarm control panel. As the
Mirage Dual Technology
is not
a complete alarm system, but only a part thereof, Texecom cannot accept
responsibility or liability for any damages whatsoever based on a claim that the
Mirage Dual Technology
failed to function correctly.
Due to our policy of continuous improvement Texecom reserves the right
to change specification without prior notice. All specifications are measured at
20˚C (68˚F).
Document Ref: M/EU/2.0-6
© 1994 - 2004 Texecom Ltd
C e r t i f i c a t e N u m b e r : F M 3 5 2 8 5
3
FALSE ALARM PROTECTION
Design:
Intelligent
A
DAPTIVE
S
IGNAL
P
ROCESSING
™ (ASP™)
.
Noise reduction circuits with maximum ground plane.
Electrostatic Discharge:
No false alarm up to 8kV air. Complies with
IEC 1000-4-2.
RF Immunity:
No false alarm from 150kHz to 1GHz at 10V/m 100%
pulsed modulation. 30V/m 80% sinusoidal modulation.
Complies with IEC 1000-4-3. Equivalent to a 270W
uniform transmitter at 10ft (3m).
Fast Transient Immunity:
No false alarm up to 4kV. Complies with IEC 1000-4-4.
RF Common Mode
Clamp:
No false alarms 150kHz to 80MHz. Complies with
IEC 1000-4-6.
Conducted Emissions:
Complies with IEC CISPR 22.
Radiated Emissions:
Complies with IEC CISPR 22, FCC Part 15.
EMC:
Independently certified to EN 50130-4 : 1996.
Microwave Range:
Internal pot to adjust.
Approvals:
Complies with: MPT 1349, I-ETS 300 440, FCC Part 15.
Pulse Count:
Internal link to select.
INS 044-6
MIN
MIN MAX
JP1
0.3 - 3.0m/s
A
B
C
D
E
F
G
H
<24V
DC
50mA
(N/C)
<24V
DC
50mA
, 18
Ω
(N/C)
9-16V
DC
20mA @ 12V
DC
Latch Input F
unctions
(see Section 5)
R
emote LED:
12V 0V/NC
RL
LA
0V
12V
ALARM
TAMP
✗
MIN
MAX
MIN MAX
MAX
JP1
✗
5
REMOTE LED & LATCH INPUT
FUNCTIONS
The latch terminal (see Section 4) can perform several different functions
depending on how it is connected:
Latch connected to Set Positive (SW+, Set+):
The LEDs will be disabled while
the system is set. Any detectors triggered while the system is set will indicate
this by permanently lighting the Alarm LED (upon unsetting the system).
Detectors can be reset by taking the latch line high and then low again.
Latch connected to Alarm Positive (AL+, A+ve):
The first detector activated
while the system is set will indicate this with a slowly flashing Alarm LED
(upon unsetting the system). Detectors which activated subsequently will
indicate this by permanently lighting the Alarm LED. Detectors can be
reset by taking the latch line high and then low again.
The latch input is not suitable for use on entry/exit or walk through zones.
Remote LED:
Connect RL to12V to disable the walk test LEDs.
Connect RL to 0V or leave unconnected to enable the walk test LEDs.
MW
ALARM
PIR
➞
➞
PULSE COUNT
2
1
LED OFF
LED ON
IMPORTANT
Ensure Microwave Range is set at correct level for
desired coverage
MIN MAX
JP1
1 - 10ft/s
Dual Technology Microwave & Infrared Detector
I N S TA L L AT I O N I N S T R U C T I O N S
www.texe.com
T H A N K Y O U F O R V O T I N G T E X E C O M
Ask your distributor today for the new Texecom full colour Product Guide.
✓
✓
W I N N E R