Low Voltage Test Procedure Example
17
SLUUC64 – June 2020
Copyright © 2020, Texas Instruments Incorporated
UCC5870QDWJEVM-026 Evaluation Module User’s Guide
16. In active state, generate a double pulse test, faults status will become red since no IGBT is
connected and connector for IGBT collector terminal is floating.
Figure 19. GUI Active Stage Fault Indicator
17.
shows the waveforms of the Desat fault, CH4 is the desat pin voltage, when it reaches
about 9.5V, the fault is triggered and nFLT1 pin is pulled low.
Figure 20. DESAT Fault Test Waveforms