describes and lists the connections and configuration for J6. Use J6 to switch between different DCL
connections to test different duty cycle limits. Pin 1 is noted by the dot next to the pin.
Table 3-2. J6 Connections and Configuration
Pin Connection
Duty Cycle Limit Configuration
Description
Pin 1 and Pin 2
100%
DCL is connected high to VLDO,
Used for TPS7H5001/2/3 EVM variants
Pin 2 and Pin 3
50%
DCL is connected low to AVSS,
Used for TPS7H5001/4 EVM variants
Floating
75%
DCL is left floating,
Used for TPS7H5001/2/3 EVM variants
EVM Connectors and Test Points
SLVUCD0 – FEBRUARY 2022
TPS7H500x-SP Evaluation Module User's Guide
9
Copyright © 2022 Texas Instruments Incorporated