4.5 Input Voltage Ripple
• Trigger CH1 of the oscilloscope on Phase Node and put the CH2 scope probe between test point TP6 (PVIN)
and TP23 (GND).
, the voltage ripple (ignoring the switching coupling to the input) is approximately 50 mV.
Figure 4-6. Input Voltage Ripple, VIN = 5 V, VOUT = 2.5 V, IOUT = 3 A
TPS7H4002EVM-CVAL Testing
10
TPS7H4002EVM-CVAL Evaluation Module
SLVUBI1 – MAY 2021
Copyright © 2021 Texas Instruments Incorporated