ADS1282-SP GUI Software in Detail
21
SBAU274 – July 2016
Copyright © 2016, Texas Instruments Incorporated
ADS1282-SP Evaluation Module (ADS1282EVM-CVAL)
If an MSP430 clock is the desired clock source, there are twelve discrete clock rates available from the
drop-down menu as shown in
. Ensure the jumpers have been moved to use this configuration.
Figure 21. ADS1282-SP GUI Quick Start STEP-2
It is also possible for the user to specify and supply a clock to the EVM. This is required if coherent
sampling is desired where the phase relationship between the analog signal and the clock signal is
deterministic. The desired frequency is entered and is constrained to values between 1000 kHz and 4096
kHz. Any value entered outside this range will default to this min or max value.
Figure 22. ADS1282-SP GUI Quick Start Step 2