3.1.14

TP2 – IN_S

Input sense test point.

3.1.15

TP3 – OUT_S

Output sense test point.

3.1.16

TP4 – EN

Enable test point.

3.1.17

TP5 – GND

Ground test point.

3.1.18

TP6 – GND

Ground test point.

3.2

Soldering Guidelines

To avoid damaging the integrated circuit (IC), use a hot-air system for any solder rework to modify the
EVM for repair or other application reasons.

3.3

Equipment Connection

1. Set the input power supply to 3.3 V (maximum) and turn the power supply off.

2. Set the bias power supply to 5.5 V (maximum) and turn the power supply off.

3. Connect the positive voltage lead from the input power supply to IN at the J5 connector of the EVM.

4. Connect the ground lead from the input power supply to GND at the J10 connector of the EVM.

5. Connect the positive voltage lead from the bias power supply to BIAS at the J3 connector of the EVM.

6. Connect the ground lead from the bias power supply to GND at the J1 connector of the EVM.

7. Connect a 0-A to 300-mA load between OUT and GND.

8. Float J9 and short J12 to disable the output.

4

Operation

1. Turn on the power supplies.

2. Short J9 (the EN pin) to IN or BIAS and float J12 to enable the output.

3. Vary the respective load and input voltage for test purposes if necessary.

Содержание TPS7A10EVM-004

Страница 1: ...TPS7A10EVM 004 Evaluation Module User s Guide Literature Number SBVU040 February 2018...

Страница 2: ...low dropout linear regulator LDO Setup and operating instructions thermal and layout guidelines a printed circuit board PCB layout a schematic diagram and a bill of materials BOM are included in this...

Страница 3: ...ng warnings and cautions are noted for the safety of anyone using or working close to the TPS7A10EVM 004 Observe all safety precautions Warning Warning Hot surface Contact may cause burns Do not touch...

Страница 4: ...or Twist together the positive input lead and ground return lead from the input power supply and keep the leads as short as possible to minimize input inductance 3 1 6 J6 OUT Regulated output voltage...

Страница 5: ...d turn the power supply off 2 Set the bias power supply to 5 5 V maximum and turn the power supply off 3 Connect the positive voltage lead from the input power supply to IN at the J5 connector of the...

Страница 6: ...t Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS7A10EVM 004 Evaluation Module 5 PCB Layout Figure 1 to Figure 3 show the PCB layout for this EVM Figure 1 Assembly Layer Figur...

Страница 7: ...w ti com Schematic 7 SBVU040 February 2018 Submit Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS7A10EVM 004 Evaluation Module 6 Schematic Figure 4 is the schematic for this E...

Страница 8: ...Schematic www ti com 8 SBVU040 February 2018 Submit Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS7A10EVM 004 Evaluation Module Figure 4 TPS7A10EVM 004 Schematic...

Страница 9: ...om Bill of Materials 9 SBVU040 February 2018 Submit Documentation Feedback Copyright 2018 Texas Instruments Incorporated TPS7A10EVM 004 Evaluation Module 7 Bill of Materials Table 1 shows the BOM for...

Страница 10: ...Rata J1 J10 J11 3 Standard Banana Jack Insulated Black 6092 6092 Keystone J3 1 BANANA JACK 15A Insulated Nylon Yellow 940x438x438 mil 108 0907 001 Cinch Connectivity J4 J12 2 Header 2 54 mm 2x1 Gold R...

Страница 11: ...11 SBVU040 February 2018 Submit Documentation Feedback TPS7A10EVM 004 Evaluation Module...

Страница 12: ...ct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer...

Страница 13: ...set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that...

Страница 14: ...the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain great...

Страница 15: ...t the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the...

Страница 16: ...OST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF...

Страница 17: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Отзывы: