Adjustment by Switch
2-2
2.1
Adjustment by Switch
-
S1 toggles between high (direction labelling) or low transient generator
frequency.
-
S2 switches the transient generator on (direction labelling) and off.
-
S3 toggles between slower (direction labelling) and faster transients.
-
S4 directs transients either to DUT1 (direction labelling) or DUT2.
2.2
Adjustment by Jumper
Table 2–1 lists adjustments that can be made by jumpers.
Table 2–1. Jumper Functions
Function/Device
DUT1
DUT2
Bypasses input resistor
JP1
JP10
Enables DUT
JP2
JP7
Bypasses ESR emulation
JP3
JP8
Set minimum load
JP4
JP9
Set maximum load
JP5
JP11
Toggles between input voltage (direction trimmer) and load
transient
JP6
JP12
2.3
Adjustment by Trimmer
Table 2–2 lists the adjustments that can be made by trimmer.
Table 2–2. Trimmer Adjustments
Function/Device
DUT1
DUT2
Risetime of transient
R15
R32
Input voltage spike transient impact
R12
R28
2.4
Adjustment by Programming Header
The programming header can be used to program the frequency and the duty
cycle of the transient generator. Table 2–3 lists the timing equations.