background image

www.ti.com

4

4

EVM Use Restrictions and Warnings:

4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT

LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.

4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling

or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.

4.3

Safety-Related Warnings and Restrictions:

4.3.1

User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.

4.3.2

EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.

4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,

state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.

5.

Accuracy of Information:

To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate

as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT

LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE

CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

Содержание TPS65987DDJ

Страница 1: ...nt contains an introduction setup conditions the EVM schematics top and bottom board layouts and component views layout and a bill of materials BOM Figure 1 Front Layout Figure 2 Back Layout Trademark...

Страница 2: ...and J6 USB Type C Plugs These USB Type C plugs can be connected to any USB Type C receptacle for a valid connection 2 10 J3 USB Type A Plug This plug is located in the board to allow data transfer fr...

Страница 3: ...a barrel jack power supply of 20 VOUT 3 A IOUT minimum into J10 Next connect the J1 USB Type C plug into a USB Type C receptacle that is PD compliant After the connection depending on the sinking cha...

Страница 4: ...USB C PD TKT EVM Schematics www ti com 4 SLVUBQ7 August 2019 Submit Documentation Feedback Copyright 2019 Texas Instruments Incorporated USB Type C PD TKT Evaluation Module Figure 6 LED Control...

Страница 5: ...com USB C PD TKT EVM Schematics 5 SLVUBQ7 August 2019 Submit Documentation Feedback Copyright 2019 Texas Instruments Incorporated USB Type C PD TKT Evaluation Module Figure 7 Type A to USB Type C Con...

Страница 6: ...Schematics www ti com 6 SLVUBQ7 August 2019 Submit Documentation Feedback Copyright 2019 Texas Instruments Incorporated USB Type C PD TKT Evaluation Module Figure 8 Plug to Receptacle Figure 9 Recepta...

Страница 7: ...KT Evaluation Module 5 USB C PD TKT EVM Board Layout Figure 10 through Figure 21 show the USB C PD TKT EVM PCB layout images Figure 10 USB C PD TKT EVM Top Overlay Figure 11 USB C PD TKT EVM Top Solde...

Страница 8: ...t 2019 Texas Instruments Incorporated USB Type C PD TKT Evaluation Module Figure 16 USB C PD TKT EVM Power 1 Figure 17 USB C PD TKT EVM Power 2 Figure 18 USB C PD TKT EVM Plane 3 Figure 19 USB C PD TK...

Страница 9: ...uF CAP CERM 6 8 uF 25 V 10 X5R 0603 0603 C1608X5R1E685K080AC TDK C15 1 10 uF CAP CERM 10 uF 35 V 20 X5R 0603 0603 GRM188R6YA106MA73D MuRata C16 C17 2 47 uF CAP TA 47 uF 35 V 10 0 3 SMD 7343 43 T495X4...

Страница 10: ...R2 R6 R14 R30 4 249 k RES 249 k 1 0 063 W AEC Q200 Grade 0 0402 0402 CRCW0402249KFKED Vishay Dale R3 1 26 7 k RES 26 7 k 1 0 05 W 0201 0201 RC0201FR 0726K7L Yageo America R4 R10 R15 R31 R55 R62 6 10...

Страница 11: ...ade 0 0402 0402 CRCW04022M00FKED Vishay Dale R52 1 69 8 k RES 69 8 k 1 0 1 W AEC Q200 Grade 0 0603 0603 CRCW060369K8FKEA Vishay Dale R56 1 301 k RES 301 k 1 0 1 W AEC Q200 Grade 0 0603 0603 CRCW060330...

Страница 12: ...e Manufacturer U8 1 Automotive Grade 4 5 35V Hysteretic Non Synchronous PFET Buck Controller with Enable Pin DGK0008A VSSOP 8 DGK0008A LM3489QMM NOPB Texas Instruments Texas Instruments U9 1 22 V Prec...

Страница 13: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 14: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 15: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 16: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 17: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 18: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...

Отзывы: