Getting Started
10
SLVUB61 – July 2017
Copyright © 2017, Texas Instruments Incorporated
TPS65291 EVM User's Guide
Figure 6. B2_Enreg is Enabled by Default in IPG-UI
•
Change the
B1_Enreg
position from
Disabled
to
Enabled
while the red voltage lead of the DMM is still
on J7 (B1_VOUT), and then click the
W
button in the
Register0
row to write new values to only this
register.
shows that bit 0 now has a value of 1b,
B1_Enreg
is
Enabled
, and that until the
W
button is clicked the changes made have not yet been written to the TPS65291 device.
–
Measure (with the DMM) and verify the voltage at J7 is approximately 3 V.
Figure 7. Enabling BUCK1 (B1_Enreg) in IPG-UI
•
Move the red voltage lead of the DMM to J11 (LDO_SW_VOUT), change the
LDOnSW_Enreg
position from
Disabled
to
Enabled
, and then click the
W
button in the
Register0
row.
shows
that bit 2 now has a value of 1b,
LDOnSW_Enreg
is
Enabled
, and that after the
W
button is pressed
all changes made by the user in the GUI have been written to the TPS65291 device. If more than one
register is changed at a time, then the
Write All
function will be faster than writing to each register one
at a time.
–
Measure (with the DMM) and verify the voltage at J11 is approximately 2.8 V, or 5 to 10 mV below
B2_VOUT because LDO_SW is configured as a load switch by default.