4-2
4.1
Setup of the EVM
Figure 4–1. Setup of the EVM
Current Meter
for Input Current
(See Note A)
+
–
Power
Supply
Oscilloscope
for Output Voltage
and Output Ripple
Voltage Meter for
LBO Output Voltage
Voltage Meter
for Input Voltage
Current Meter
for Output Current
Important
LOAD
Note A: Use this current meter only if the sense wires of the supply are used.
Follow these steps for proper operation of the EVM:
1) Connect J1, the Enable-pin, with V
DD
as shown in Figure 4–1.
2) Connect the sense wires of the power supply to the input terminals of the
board, or solder the connections of the power supply to the terminals.
3) Connect the input voltage meter between the board on the one side and
the power supply and input current meter on the other side.
4) Connect the oscilloscope between the output terminals of the EVM on the
one side and the load and output current meter on the other side.
Содержание TPS6100 EVM Series
Страница 1: ... May 2000 Power Management Products User s Guide SLVU029 ...
Страница 6: ...vi ...
Страница 8: ...1 2 ...
Страница 14: ...3 4 ...
Страница 15: ...4 1 Setup of the EVM Topic Page 4 1 Setup of the EVM 4 2 4 2 Low Battery Function LBI and LBO 4 3 Chapter 4 ...
Страница 18: ...4 4 ...