EVM Test Setup
6
SLUUC03 – February 2019
Copyright © 2019, Texas Instruments Incorporated
TPS566235EVM-036 evaluation module
Figure 6. Board Layout (Bottom Layer)
5
EVM Test Setup
This section describes how to properly connect, set up, and use TPS566235EVM-036 evaluation module.
5.1
Connectors and Jumpers Description and Placement
TPS566235EVM-036 is provided with input/output connectors and test points as listed in
. And
and
shows connectors and jumpers placement on TPS566235EVM-036 board.
A power supply capable of supplying greater than 5 A must be connected to J1 through a pair of 20-AWG
wires. The load must be connected to J2 through a pair of 20-AWG wires. The maximum load current
capability is 6 A. Wire lengths must be minimized to reduce losses in the wires. Test point TP2 provides a
place to monitor the V
IN
input voltages with TP4 providing a convenient ground reference. TP6 is used to
monitor the output voltage with TP13 as the ground reference.