9 EVM Configuration Using the Fusion GUI
The TPS549D22 installed on this EVM leave the factory pre-configured. See
for a short list of key
factory configuration parameters as obtained from the configuration file.
Table 9-1. Key Factory Configuration Parameters
Cmd ID With Phase
Cmd Code Hex
Encoded Hex
[HiByte|LoByte]
Comments
CAPABILITY
0x19
0xD0
Max Bus: 1000 khz; PEC: Yes; SMBALERT#: Yes
MFR_00
0xD0
0x00
0
MFR_01
(PGOOD_DLY)
0xD1
0x12
PGD:1024?s [010b], POD:1024?s [010b]
MFR_02
0xD2
0x13
CM: True, HICLOFF: True, SST: 0x00, FORCESKIPSS: True,
SEQ: False, TRK: False
MFR_03
0xD3
0x93
FS:625kHz [011b], RCSP:R ? 1 [01b], DCAP3:True
MFR_04
0xD4
0x80
DCAP3_Offset:0mV [00b], DCAP3_Offset_Sel:True
MFR_06
0xD6
0x05
VDDUVLO:4.25V [101b]
MFR_07
0xD7
0x8F
VTRKIN:1.25V [1111b], TRKOPTION:False, SPARE:False,
VPBAD:True
MFR_33
0xF1
0x00
0
MFR_42
0xFA
0x00
0
MFR_44
0xFC
0x0201
ID: 0x020 (TPS549C20), Revision: 0x1
ON_OFF_CONFIG
0x02
0x17
Mode: CONTROL Pin Only; Control: Active High, Turn off
Immediately
OPERATION
0x01
0x00
Operation is not used to enable regulatio; Unit: ImmediateOff;
Margin: None
STATUS_BYTE
0x78
0x00
Status: Output Off, Vout OV Fault, IOUT OC Fault, Vin UV
Fault, Temperature, CML
STATUS_CML
0x7E
0x00
Status: Invalid Command, Invalid Data, PEC Fault, Other
Comms Fault
STATUS_IOUT
0x7B
0x00
Status: Iout OC Fault, Iout OC Fault with LV Shutdown, Iout
UC Fault
STATUS_VOUT
0x7A
0x00
Status: Vout OV Fault, OV Warning, UV Fault, UV Warning
VOUT_COMMAND
0x21
0x01CD
VOUT_COMMAND=0.900 V
VOUT_MARGIN_HIGH
0x25
0x0266
VOUT_MARGIN_HIGH=1.199 V
VOUT_MARGIN_LOW
0x26
0x0266
VOUT_MARGIN_LOW=1.199 V
WRITE_PROTECT
0x10
0x00
Enable Writes To All Commands
If it is desired to configure the EVM to settings other than the factory settings shown in Table 3, the TI Fusion
Digital Power Designer software can be used for reconfiguration. It is necessary to have input voltage applied
to the EVM prior to launching the software so that the TPS549D22 installed is active and able to respond to the
GUI and the GUI can recognize the device.
EVM Configuration Using the Fusion GUI
SLUUBG4A – JULY 2016 – REVISED AUGUST 2021
TPS549D22 SWIFT™ Step-Down Converter Evaluation Module User's Guide
11
Copyright © 2021 Texas Instruments Incorporated