2.6 Loop Characteristics
The TPS54331EVM-232 loop-response characteristics are shown in
. Gain and phase plots are
shown for VIN voltage of 15 V. Load current for the measurement is 1.5 A.
-30
-20
-10
0
10
20
30
40
50
60
70
f - Frequency - Hz
-90
-60
-30
0
30
60
90
120
150
180
210
Phase-deg
10
100
1k
10k
100k
1M
Gain-dB
Figure 2-6. TPS54331 Loop Response
2.7 Output Voltage Ripple
The TPS54331EVM-232 output voltage ripple is shown in
. The output current is the rated full load of
3 A. Voltage is measured directly across output capacitors.
V
OUT
PH
t - Time - 1
s/div
m
Figure 2-7. TPS54331 Output Ripple