1.3 Modifications
These evaluation modules are designed to provide access to the features of the TPS54326. Some modifications
can be made to this module.
1.3.1 Output Voltage Set Point
To change the output voltage of the EVMs, it is necessary to change the value of resistor R1. Changing the
value of R1 can change the output voltage above 0.765V. The value of R1 for a specific output voltage can be
calculated using
For output voltage from 0.76V to 2.5V:
O
R1
V
= 0.765
1+
R2
æ
ö
´ ç
÷
è
ø
(1)
For output voltage over 2.5V:
O
O
R1
V
= (0.763 + 0.0017
V )
1+
R2
æ
ö
´
´ ç
÷
è
ø
(2)
lists the R1 value for some common output voltages. For higher output voltages, a feed forward
capacitor is required. Pads for this component (C2) are provided on the printed circuit board. C2 is used for
faster load transient response and is recommended for auto skip mode stability. Note that the values given in
are standard values, and not the exact value calculated using
Table 1-3. Output Voltages
Output Voltage
(V)
R1
(kΩ)
R2
(kΩ)
C2
(pF)
L1
(µH)
1.0
6.81
22.1
1.5
1.05
8.25
22.1
1.5
1.2
12.7
22.1
1.5
1.8
30.1
22.1
10 - 47
2.2
2.5
49.9
22.1
10 - 47
2.2
3.3
73.2
22.1
10 - 47
2.2
5.0
121
22.1
10 - 47
3.3
Introduction
SLVU353A – NOVEMBER 2009 – REVISED OCTOBER 2021
TPS54326 Step-Down Converter Evaluation Module User's Guide
3
Copyright © 2021 Texas Instruments Incorporated