![Texas Instruments TPS54320 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/texas-instruments/tps54320/tps54320_user-manual_1095368009.webp)
2.9 Powering Up
and
show the start-up waveforms for the TPS54320. In
ramps up as soon as the input voltage reaches the UVLO threshold as set by the R1 and R2 resistor divider
network. In
, the input voltage is initially applied and the output is inhibited by using a jumper
at JP2 to tie EN to GND. When the jumper is removed, EN is released. When the EN voltage reaches the
enable-threshold voltage, the start-up sequence begins and the output voltage ramps up to the externally set
value of 3.3 V. The input voltage for these plots is 12 V and the load is 1.1Ω.
V
= 10 V/div
IN
EN = 2 V/div
SS/TR = 1 V/div
V
= 2 V/div
OUT
t - Time - 2 ms/div
Figure 2-9. TPS54320 Start-Up Relative to V
IN
V
= 10 V/div
IN
EN = 2 V/div
SS/TR = 1 V/div
V
= 2 V/div
OUT
t - Time - 2 ms/div
Figure 2-10. TPS54320 Start-Up Relative to Enable
Test Setup and Results
SLVU380A – SEPTEMBER 2010 – REVISED OCTOBER 2021
TPS54320 Step-Down Converter Evaluation Module User's Guide
9