3.1 Enable Jumpers (JP1 and JP2)
The TPS54291EVM-431 provides separate three pin 100-mil headers and shunts for exercising the TPS54291
Enable functions. Place the JP1 shunt in the left position connects EN1 to ground and turns on Output 1 and
placing the JP2 shunt in the left position connects EN2 to ground and turns on Output 2.
3.2 Error Amplifier Outputs
The output of the TPS54291 transconductance error amplifiers (COMP1 and COMP2) are sensitive to
capacitive loading, including the typical 8-pF to 15-pF capacitance added by an oscilloscope probe. No direct
measurements of these signals should be attempted without using an external buffer to prevent loading of the
control voltage.
3.3 Test Point Descriptions
Table 3-1. Test Point Descriptions
TEST POINT
LABEL
USE
SECTION
TP1
VIN
Monitor Input Voltage
TP2
GND
Ground for Input Voltage
TP3
VOUT1
Monitor VOUT1 Voltage
TP4
GND
Ground for VOUT1 Voltage
TP5
GND
Ground for VOUT1 Channel B Loop Monitoring
TP6
CHB
VOUT1 Channel B for Loop Monitoring
TP7
GND
Ground for VOUT1 Channel A Loop Monitoring
TP8
CHA
VOUT1 Channel B for Loop Monitoring
TP9
SW1
Monitor Switching Node of Channel 1
TP10
GND
Ground for Switch Node of Channel 1
TP11
IC_GND
Monitor IC Ground
TP12
SW2
Monitor Switching Node of Channel 2
TP13
GND
Ground for Switch Node of Channel 2
TP14
CHA
VOUT2 Channel A for Loop Monitoring
TP15
GND
Ground for VOUT2 Channel A Loop Monitoring
TP16
CHB
VOUT2 Channel B for Loop Monitoring
TP17
GND
Ground for VOUT2 Channel B Loop Monitoring
TP18
VOUT2
Monitor VOUT2 Voltage
TP19
GND
Ground for VOUT2 Voltage
3.3.1 Input Voltage Monitoring (TP1 and TP2)
TPS54291EVM-431 provides two test points for measuring the voltage applied to the module. This allows the
user to measure the actual module voltage without losses from input cables and connectors. All input voltage
measurements should be made between TP1 and TP2. To use TP1 and TP2, connect a voltmeter positive
terminal to TP1 and negative terminal to TP2.
3.3.2 Channel 1 Output Voltage Monitoring (TP3 and TP4)
TPS54291EVM-431 provides two test points for measuring the voltage generated by the module. This allows
the user to measure the actual module output voltage without losses from output cables and connectors. All
output voltage measurements should be made between TP3 and TP4. To use TP3 and TP4, connect a voltmeter
positive terminal to TP3 and negative terminal to TP4. For output ripple measurements, TP3 and TP4 allow a
user to limit the ground loop area by using the tip and barrel measurement technique shown in
.
All output ripple measurements should be made using the tip and barrel measurement. Even this Tip and Barrel
measurement technique increases the measured switch edge noise. For improved output ripple measurement,
measure the output ripple at the output capacitor (C5).
Schematic
SLVU356A – JANUARY 2010 – REVISED OCTOBER 2021
TPS54291 Step-Down Converter Evaluation Module User's Guide
5
Copyright © 2021 Texas Instruments Incorporated