Test Procedure
7.3
List of Test Points
Table 4. The Functions of Each Test Points
TEST POINTS
NAME
DESCRIPTION
TP1
CHA
Input A for Loop Injection
TP2
CHB
Input B for Loop Injection
TP3
VREG3
3.3-V Internal LDO Output
TP4
GND
GND
TP5
GND
GND
TP6
VIN
Input Voltage
TP7
VOUT
Output Voltage
TP8
SW
Switching Node
TP9
GND
GND
TP10
GND
GND
TP11
EN
Enable Pin
TP12
PGD
Power Good Output
7.4
Equipment Shutdown
1. Shut down VIN.
2. Shut down Load.
3. Shut down FAN.
9
SLUU671
–
December 2011
5-A Step-Down Regulator with Integrated Switcher
Copyright
©
2011, Texas Instruments Incorporated