7 Test Procedure
7.1 Line/Load Regulation and Efficiency Measurement Procedure
1. Set up the EVM as described in
and
.
2. Ensure Load is set to constant resistance mode and to sink 0 A
DC
.
3. Ensure the switch S1 is set per
.
4. Increase VIN from 0 V to 12 V. Using V1 to measure VIN voltage.
5. Set the switch S1 to Enable position to enable the controller.
6. Use V2 to measure VOUT voltage, A1 to measure VIN current.
7. Vary load from 0 A
DC
to 8 A
DC
. V
OUT
should remain in load regulation.
8. Vary V
IN
from 8.0 V to 22 V. V
OUT
should remain in line regulation.
9. Set the switch S1 to Disable position to disable the controller.
10. Decrease load to 0 A.
11. Decrease VIN to 0 V.
7.2 List of Test Points
Table 7-1. Test Point Functions
TEST POINTS
NAME
DESCRIPTION
TP1
VIN
Input voltage
TP2
GND
GND
TP3
VREG5
Output of 5-V linear regulator
TP4
SS
Soft-start ramp voltage
TP5
EN
Enable pin
TP6
SW
Switching node
TP7
VOUT
Output voltage
TP8
GND
GND
TP9
GND
GND
TP10
GND
GND
7.3 Equipment Shutdown
1. Shut down VIN.
2. Shut down Load.
3. Shut down FAN.
Test Procedure
SLUU943A – MAY 2012 – REVISED DECEMBER 2021
TPS53014 Buck Controller Evaluation Module User's Guide
7