background image

www.ti.com

Bill Of Materials (BOM)

11

SLVUBA5 – October 2017

Submit Documentation Feedback

Copyright © 2017, Texas Instruments Incorporated

TPS26624-25 Evaluation Module

ADVANCE INFORMATION

6

Bill Of Materials (BOM)

Table 8

lists the EVM BOM.

Table 8. TPS26624-25EVM Bill of Materials

Designator

QTY

Value

Description

Package Reference

Part Number

Manufacturer

!PCB1

1

Printed Circuit Board

PSIL028

Any

C1, C6

2

1uF

CAP, CERM, 1 µF, 100 V, ±10%, X7R, 1206

1206

GRM31CR72A105KA01L

Murata

C2, C7

2

2.2uF

CAP, CERM, 2.2 µF, 100 V, ±10%, X7R, 1210

1210

GRM32ER72A225KA35L

Murata

C3, C8

2

0.022uF

CAP, CERM, 0.022 µF, 16 V,±10%, X7R, 0603

0603

GRM188R71C223KA01D

Murata

C4, C5, C9, C10

4

10uF

CAP, CERM, 10 µF, 63 V, ±10%, X7R, 1210

1210

GRM32ER71J106KA12L

Murata

D2, D4, D8, D10

4

33V

Diode, TVS, Bi, 33 V, SMB

SMB

SMBJ33CA-13-F

Diodes Inc.

D5, D11

2

Red

LED, Red, SMD

Red LED, 1.6x0.8x0.8mm

LTST-C190CKT

Lite-On

D6, D12

2

Green

LED, Green, SMD

1.6x0.8x0.8mm

LTST-C190GKT

Lite-On

H1, H2, H3, H4

4

Bumpon, Hemisphere, 0.44 X 0.20, Clear

Transparent Bumpon

SJ-5303 (CLEAR)

3M

J1, J2, J3, J5, J6, J7

6

Header, 100mil, 2x1, Gold, TH

Sullins 100mil, 1x2, 230 mil
above insulator

PBC02SAAN

Sullins Connector Solutions

J4, J8

2

Header, 100mil, 5x2, Tin, TH

Header, 5x2, 100mil, Tin

PEC05DAAN

Sullins Connector Solutions

R1, R11

2

49.9k

RES, 49.9 k, 1%, 0.1 W, 0603

0603

CRCW060349K9FKEA

Vishay-Dale

R2, R12

2

887k

RES, 887 k, 1%, 0.1 W, 0603

0603

CRCW0603887KFKEA

Vishay-Dale

R3, R13

2

29.4k

RES, 29.4 k, 1%, 0.1 W, 0603

0603

CRCW060329K4FKEA

Vishay-Dale

R4, R14

2

24.3k

RES, 24.3 k, 1%, 0.1 W, 0603

0603

CRCW060324K3FKEA

Vishay-Dale

R5, R15

2

34.0k

RES, 34.0 k, 1%, 0.1 W, 0603

0603

CRCW060334K0FKEA

Vishay-Dale

R6, R16

2

7.50k

RES, 7.50 k, 1%, 0.1 W, 0603

0603

CRCW06037K50FKEA

Vishay-Dale

R7, R17

2

13.3k

RES, 13.3 k, 1%, 0.1 W, 0603

0603

CRCW060313K3FKEA

Vishay-Dale

R8, R18

2

26.7k

RES, 26.7 k, 1%, 0.1 W, 0603

0603

CRCW060326K7FKEA

Vishay-Dale

R10, R20

2

267k

RES, 267 k, 1%, 0.1 W, 0603

0603

CRCW0603267KFKEA

Vishay-Dale

S1, S2

2

Switch, SPST-NO, Off-Mom, 0.05A, 12VDC, SMD

3.9x2.9mm

PTS820 J20M SMTR LFS

C&K Components

SH-J1, SH-J2, SH-J3, SH-J4,
SH-J5, SH-J6, SH-J7, SH-J8

8

1x2

Shunt, 100mil, Flash Gold, Black

Closed Top 100mil Shunt

SPC02SYAN

Sullins Connector Solutions

T1, T2, T3, T4

4

Terminal Block, 2x1, 5.08mm, TH

10.16x15.2x9mm

282841-2

TE Connectivity

TP1, TP2, TP8, TP9

4

White

Test Point, TH, Multipurpose, White

Keystone5012

5012

Keystone

TP3, TP4, TP10, TP11

4

Red

Test Point, Multipurpose, Red, TH

Red Multipurpose Testpoint

5010

Keystone

TP5, TP6, TP7, TP12, TP13,
TP14

6

SMT

Test Point, SMT, Compact

Testpoint_Keystone_Compact

5016

Keystone

U1

1

7V - 57V, 800mA Industrial eFuse with Integrated Reverse Polarity
Protection, DRC0010J (VSON-10)

DRC0010J

TPS26624DRCR

Texas Instruments

U2

1

7V - 57V, 800mA Industrial eFuse with Integrated Reverse Polarity
Protection, DRC0010J (VSON-10)

DRC0010J

TPS26625DRCR

Texas Instruments

D3, D9

0

51V

Diode, TVS, Bi, 51 V, SMA

SMA

SMAJ51CA

Littelfuse

FID1, FID2, FID3

0

Fiducial mark. There is nothing to buy or mount.

Fiducial

N/A

N/A

R9, R19

0

44.2k

RES, 44.2 k, 1%, 0.1 W, 0603

0603

CRCW060344K2FKEA

Vishay-Dale

Содержание TPS26624

Страница 1: ...try 7 4 Output Short Circuit Protection 8 5 TPS26624 25EVM Top Side Placement 9 6 TPS26624 25EVM Bottom Side Placement 9 7 TPS26624 25EVM Top Layer Routing 10 8 TPS26624 25EVM Bottom Layer Routing 10...

Страница 2: ...llowing applications Control and automation Industrial power systems Sensors controls PLCs 2 Description The TPS26624 25EVM enables full evaluation of the TPS26624 25 devices This EVM has two independ...

Страница 3: ...N 1 UVLO 2 OVP 3 SHDN 4 RTN 5 GND 6 ILIM 7 DVDT 8 FLT 9 OUT 10 PAD 11 U1 TPS26624DRCR IN 1 UVLO 2 OVP 3 SHDN 4 RTN 5 GND 6 ILIM 7 DVDT 8 FLT 9 OUT 10 PAD 11 U2 TPS26625DRCR 2 1 S2 2 1 S1 GND GND 267k...

Страница 4: ...b1 FLTb2 Fault indicator TP2 TP9 SHDNb1 SHDNb2 Shutdown signal TP3 TP10 VIN1 VIN2 Power supply input TP4 TP11 VOUT1 VOUT2 eFuse output TP5 TP12 GND GND TP6 TP13 TP7 TP14 Table 4 Jumper and LED Descrip...

Страница 5: ...rporated TPS26624 25 Evaluation Module ADVANCE INFORMATION NOTE A resistive load is recommended for testing If an electronic load is used ensure that it is set in the constant resistance CR mode not i...

Страница 6: ...put load is set to constant resistance mode and not constant current mode NOTE Measuring Current Limit values on the oscilloscope can easily cause 8 error from anticipated values listed in Table 5 2 T...

Страница 7: ...rcuit protection feature of the device 1 Set the oscilloscope as shown in Table 7 on CH1 Table 7 TPS26624 25EVM Oscilloscope Setting for Output Short Circuit Protection Oscilloscope Setting CH1 Probe...

Страница 8: ...5 Evaluation Module ADVANCE INFORMATION 2 Set the power supply on CH1 to 24 V and the load resistance on CH1 to 120 1 3 Enable the load and the power supply on CH1 4 Use either thick wire or a screw d...

Страница 9: ...2017 Texas Instruments Incorporated TPS26624 25 Evaluation Module ADVANCE INFORMATION 5 EVM Board Assembly Drawings and Layout Guidelines 5 1 PCB Drawings Figure 5 through Figure 8 show the component...

Страница 10: ...www ti com 10 SLVUBA5 October 2017 Submit Documentation Feedback Copyright 2017 Texas Instruments Incorporated TPS26624 25 Evaluation Module ADVANCE INFORMATION Figure 7 TPS26624 25EVM Top Layer Rout...

Страница 11: ...S 29 4 k 1 0 1 W 0603 0603 CRCW060329K4FKEA Vishay Dale R4 R14 2 24 3k RES 24 3 k 1 0 1 W 0603 0603 CRCW060324K3FKEA Vishay Dale R5 R15 2 34 0k RES 34 0 k 1 0 1 W 0603 0603 CRCW060334K0FKEA Vishay Dal...

Страница 12: ...set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that...

Страница 13: ...the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain great...

Страница 14: ...t the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the...

Страница 15: ...OST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF...

Страница 16: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Отзывы: