5.3 Input Undervoltage Protection Test
Use the following instructions to perform input undervoltage protection test:
1. Set dual polarity regulated power supply to +15 V : 0 V : –15 V and apply the power at connector J2
2. OPEN jumper J6
3. Connect a load of 3 kΩ between I_OUT_1 and AGND_1 at connector J3
4. Apply a voltage of 0 V at I_IN_1 and gradually decrease the voltage to –15.4 V to trigger the input
undervoltage fault
5. Observe the waveforms using an oscilloscope
shows input undervoltage protection response of TPS26610 on TPS2661EVM eFuse Evaluation
Board.
Figure 5-7. Input Undervoltage Protection Response of TPS26610 Device
Test Setup and Procedures
12
TPS2661EVM: Evaluation Module for TPS2661x
Current-Loop Protector
SLVUBX8B – OCTOBER 2020 – REVISED DECEMBER 2021
Copyright © 2021 Texas Instruments Incorporated