4.4.2 Output Voltage Start-Up Time Test
Follow the instructions to verify the individual channels output voltage start-up time:
1. Set up the oscilloscope as listed in
.
2. Set the load resistance to 16 Ω ±1 Ω and the power supply voltage to 24 V.
3. Enable the load.
4. Enable the power supply and verify that the output voltage startup waveform is as shown in
Table 4-7. TPS2640EVM Oscilloscope Setting for the Output Voltage Start-Up Test
Oscilloscope Setting
CH1 Probe Points
CH2 Probe Points
Channel 1 = 10 V / div
VOUT1 (TP3)
VOUT2 (TP12)
Channel 2 = 10 V / div
VIN1 (TP2)
VIN2 (TP11)
Channel 3 = 20 V / div
FLTb1 (TP1)
FLTb2 (TP10)
Channel 4 = 1 A / div
Input current into T1 +Ve wire
Input current into T3 +Ve wire
Trigger source = Channel 1
Trigger level = 12 V ±1 V
Trigger polarity = Rising
Trigger mode = Single
Time base
2 ms / div
Figure 4-2. Output Voltage Start-Up Waveform
General Configurations
SLVUBX9 – OCTOBER 2020
TPS2640EVM: Evaluation Module for TPS2640