Test Setup and Procedures
8
SLUUCB4 – June 2020
Copyright © 2020, Texas Instruments Incorporated
TPS25980EVM: Evaluation Module for TPS25980x efuse
5.2
Current Limit Test
Use the following instructions to perform current limit test:
1. Place jumper J9 in 3-4 Position to set 2 ms for ITIMER.
2. Set the input supply voltage VIN to 12 V and current limit of 15 A and enable the power supply.
3. Place jumper J10 in 7-8 Position to set 8 A current limit.
4. Set the electronic load to 6 A and connect between VOUT and GND. Enable the electronic load.
5. Now apply overload of 4 A (using resistive load of 3 Ohm) between VOUT and GND.
6. The device allows the overload current for the programmed ITIMER period for example, 2 ms and then
switches OFF.
7. Place jumper J10 at other settings to test at various current limits.
shows an example of current limit at 8 A on the TPS25980EVM eFuse Evaluation Board.
Figure 4. Over Current Response of TPS259804O for 8 A Current Limit Setting