background image

www.ti.com

4

4

EVM Use Restrictions and Warnings:

4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT

LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.

4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling

or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.

4.3

Safety-Related Warnings and Restrictions:

4.3.1

User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.

4.3.2

EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.

4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,

state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.

5.

Accuracy of Information:

To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate

as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT

LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE

CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

Содержание TPS16630-32EVM

Страница 1: ...t Circuit Protection 9 4 Top Side Placement 10 5 Top Layer 11 6 Bottom Layer 11 7 TPS16630 32EVM Schematic 12 List of Tables 1 SVHC Summary 2 2 TPS16630 32EVM Options and Setting 2 3 Input and Output...

Страница 2: ...rails up to 33 V and 51 V SMB TVS for 48 V power rails On board reset switch and fault indicators 1 3 Applications PLC CNC Medical Equipment Control and Automation Industrial power systems Sensors Hu...

Страница 3: ...C7 have to be replaced with diodes and capacitors of appropriate voltage rating Table 4 Test Points Description Channel Test Points Label Description CH1 TP1 FLTb1 CH1 fault indicator TP2 SHDNb1 CH1...

Страница 4: ...s respectively LED turns on when the internal MOSFET is disabled due to any fault condition such as undervoltage overvoltage overload short circuit reverse current and thermal shutdown D5 D10 GREEN LE...

Страница 5: ...mit Documentation Feedback Copyright 2018 2019 Texas Instruments Incorporated TPS16630 32EVM Evaluation Module for TPS1663x 3 3 Test Setup Figure 1 shows the typical test setup for the TPS16630 32EVM...

Страница 6: ...630 32EVM DMM Readings at Different Test Points Voltage test on CH1 Measured Voltage Reading Voltage test on CH2 Measured Voltage Reading VIN_SYS1 TP3 24 V 1 V DC VIN_SYS2 TP12 24 V 1 V DC VOUT1 TP4 2...

Страница 7: ...art Up Time Test Follow the instructions to verify the individual channels output voltage start up time 1 Set up the oscilloscope as listed in Table 9 2 Set the load resistance to 12 1 and the power s...

Страница 8: ...ion 1 2 2 The jumper setting for different current limits is shown in Table 10 Table 10 TPS16630 32EVM Jumper Setting for Current Limits CH1 CH2 Jumper Positions J4 J10 Load Current Limit A 1 2 6 3 4...

Страница 9: ...CH2 Probe Points Channel 1 10 V div VIN_SYS1 TP3 VIN_SYS2 TP12 Channel 2 10 V div VOUT1 TP4 VOUT TP13 Channel 3 20 V div FLTb1 TP1 FLTb2 TP10 Channel 4 2 A div Input current into T1 Ve wire Input curr...

Страница 10: ...019 Submit Documentation Feedback Copyright 2018 2019 Texas Instruments Incorporated TPS16630 32EVM Evaluation Module for TPS1663x 4 EVM Board Assembly Drawings and Layout 4 1 PCB Drawings Figure 4 th...

Страница 11: ...rawings and Layout 11 SLVUBI9A October 2018 Revised March 2019 Submit Documentation Feedback Copyright 2018 2019 Texas Instruments Incorporated TPS16630 32EVM Evaluation Module for TPS1663x Figure 5 T...

Страница 12: ...7 IMON2 49 9k R17 TP6 GND TP15 GND 100k R22 Red 1 2 D1 Red 1 2 D6 VOUT2 4 5V 60V IOUT2 0 6A 6A TP3 VIN1 TP12 VIN2 TP9 PGOOD1 TP18 PGOOD2 1 2 J3 DNP 1 2 J6 1 2 J9 DNP 1 2 J12 TPS16630RGER IN 1 IN 2 NC...

Страница 13: ...3CA 13 F Diodes Inc 7 D4 D9 2 60 V Diode Schottky 60 V 2 A SMB SMB B260 13 F Diodes Inc 8 D5 D10 2 Green LED Green SMD 1 6x0 8x0 8mm LTST C190GKT Lite On 9 H1 H2 H3 H4 4 Bumpon Hemisphere 0 44 X 0 20...

Страница 14: ...24 S1 S2 2 Switch SPST NO Off Mom 0 05A 12VDC SMD 3 9x2 9mm PTS820 J20M SMTR LFS CK Components 25 SH J1 SH J2 SH J4 SH J7 SH J8 SH J10 6 1x2 Shunt 100mil Flash Gold Black Closed Top 100mil Shunt SPC0...

Страница 15: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 16: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 17: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 18: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 19: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 20: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...

Отзывы: