shows that if the Analog EVM Connector is connected correctly, the status bar at the bottom of the
screen displays
Hardware Connected
. If the Analog EVM Controller is not properly connected or not connected
at all, the status bar displays
Hardware not connected
. In case the
Hardware not connected
status persists even
after the hardware is connected, go to
Options → Serial Port
, and change the port to the other available port with
the
(Texas Instruments)
or
ACCtrl
tag. Out of the two ports with these tags, one port should connect.
Figure 3-4. TPL1401EVM GUI Connection Detection
3.2.2 Software Features
The TPL1401 EVM incorporates interactive functions that help configure the TPL1401 device. These functions
are built into several GUI pages, as shown in the following sections. The
Menu
allows the user to switch between
the pages, with each page representing a feature of the software.
3.2.2.1 Home Page
shows the page providing the basic information and navigation to other pages. Click on
Learn More...
to get more information on the device.
Figure 3-5. TPL1401EVM Software Home Page
Detailed Description
SNAU257 – OCTOBER 2020
TPL1401 Evaluation Module
17