background image

Important Notice for Users of this Product in Japan

This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan

If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:

1.

Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and
Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of
Japan,

2.

Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this
product, or

3.

Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with
respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note
that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.

Texas Instruments Japan Limited

(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan

http://www.tij.co.jp

【ご使用にあたっての注】

本開発キットは技術基準適合証明を受けておりません。

本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。

1.

電波法施行規則第

6

条第

1

項第

1

号に基づく平成

18

3

28

日総務省告示第

173

号で定められた電波暗室等の試験設備でご使用いただく。

2.

実験局の免許を取得後ご使用いただく。

3.

技術基準適合証明を取得後ご使用いただく。

なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。

   上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。

日本テキサス・インスツルメンツ株式会社

東京都新宿区西新宿6丁目24番1号

西新宿三井ビル

http://www.tij.co.jp

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

Содержание TPD1E05U06DPL

Страница 1: ...e procedure outlined below ensures proper testing setup and method for both discharge tests ESD EVM FEATURED DEVICES D1 TPD4E101DPW D2 TPD1E10B09DPY 0402 D3 TPD1E6A14DPL 0201 D4 TPD1E10B06DPY 0402 D5 TPD1E6B06DPL 0201 D6 TPD1E05U06DPY 0402 D7 TPD1E05U06DPL 0201 D8 TPD5E003DPF D9 Empty D10 Empty currently unpopulated D2 and D4 are currently populated with other devices to follow soon Figure 1 ESD E...

Страница 2: ...www ti com Figure 2 ESD EVM Layout 2 ESD Protection Diodes EVM SLVU702 March 2012 Submit Documentation Feedback Copyright 2012 Texas Instruments Incorporated ...

Страница 3: ... with adjustable ranges shown in table 1 and 2 REST STRESS VOLTAGE LEVELS The IEC 61000 4 2 test level range is given in table 1 Stress tests should also be incrementally tested above level 4 until the point of failure Table 1 Test Levels Contact 1 Contact Discharge Level Test Voltage kV Air Discharge Level Test Voltage kV 1 2 1 2 2 4 2 4 3 6 3 8 4 8 4 15 1 Contact and air discharge are different ...

Страница 4: ...D simulator on the vias on one side of the EVM clamping voltage can be measured using the vias on the other side of the EVM with an oscilloscope Contact and air gap discharge are tested using the same simulator with the same discharge waveform While the simulator is in direct contact with the DUT during contact it is not during air gap Figure 4 System Level ESD Test Setup EVALUATION OF TEST RESULT...

Страница 5: ... This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti com esh No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine process or combination in which such TI products or se...

Страница 6: ...ency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES 003 rules which are designed to provide reasonable protection against radio frequency interference Operation of the equipment may cause interference with radio communications in which case the user at his own expense will be required to take whatever measures may be required t...

Страница 7: ... its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this l...

Страница 8: ...er you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product Also please do not transfer this product unless you give the same notice above to the transferee Please note that if you could not follow the instructions above you will be subject to penalties of Radio Law of Japan Texas Instruments Japan Limited address 24 1 Nishi Shi...

Страница 9: ... property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads Any loads applied outside of the specified output range may result in unintended and or inaccurate operation and or possible permanent damage to the EVM and or interface electronics Plea...

Страница 10: ...regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures monitor failures and their consequence...

Страница 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Texas Instruments ESD EVM 001 ...