Introduction

Texas Instrument’s TPD1E04U04 evaluation module helps designers evaluate the operation and
performance of the TPD1E04U04 device. The TPD1E04U04 is a unidirectional TVS ESD protection diode
for HDMI 2.0 and USB 3.0 high speed data line protection. The TPD1E04U04 is rated to dissipate ESD
strikes at the maximum level specified in the IEC 61000-4-2 international standard (Level 4).

The EVM contains six TPD1E04U04s. Five TPD1E04U04s (D1 – D5) are configured with test points for
striking ESD to the protection pins. One TPD1E04U04 (D6) is configured with 2 SMA (J1 and J2)
connectors for 2-port analysis with a vector network analyzer. TPD1E04U04 (D6) can also be used for
capturing clamping waveforms with an oscilloscope during an ESD test. Caution must be taken when
capturing clamping waveforms during an ESD event so as not to damage the oscilloscope. A proper
procedure is outlined in

Section 3.3.1

.

2

Definitions

Contact Discharge —

a method of testing in which the electrode of the ESD simulator is held in contact

with the device-under-test (DUT).

Air Discharge —

a method of testing in which the charged electrode of the ESD simulator approaches

the DUT, and a spark to the DUT actuates the discharge.

ESD Simulator —

a device that outputs IEC 61000-4-2 compliance ESD waveforms shown in

Figure 1

with adjustable ranges shown in

Table 1

and

Table 2

.

IEC 61000-4-2 has 4 classes of protection levels. Classes 1 – 4 are shown in

Table 1

Stress tests

should be incrementally tested to level 4 as shown in

Table 2

until the point of failure. If the DUT

does not fail at 8-kV, testing can continue in 2-kV increments until failure.

Table 1. IEC 61000-4-2 Test Levels

Contact Discharge

Air Discharge

Class

Test Voltage [± kV]

Class

Test Voltage [± kV]

1

2

1

2

2

4

2

4

3

6

3

8

4

8

4

15

Table 2. Waveform Parameters in Contact Discharge Mode

Stress Level Step

Simulator Voltage

[kV]

Ipeak ±15% [A]

Rise Time ±25%

[nS]

Current at 30 ns

±30% [A]

Current at 60 ns

±30% [A]

1

2

7.5

0.8

4

2

2

4

15

0.8

8

4

3

6

22.5

0.8

12

6

4

8

30

0.8

16

8

Содержание TPD1E04U04

Страница 1: ...lysis This user s guide includes setup instructions schematic diagrams a bill of materials and printed circuit board layout drawings for the evaluation module Contents 1 Introduction 2 2 Definitions 2 3 Setup 3 3 1 IEC 61000 4 2 ESD Rating Tests 3 3 2 Scattering Parameters 4 3 3 8 kV ESD Clamping Waveforms 4 4 Board Layout 6 5 Schematics 6 6 Bill of Materials 7 List of Figures 1 Ideal Contact Disc...

Страница 2: ...o as not to damage the oscilloscope A proper procedure is outlined in Section 3 3 1 2 Definitions Contact Discharge a method of testing in which the electrode of the ESD simulator is held in contact with the device under test DUT Air Discharge a method of testing in which the charged electrode of the ESD simulator approaches the DUT and a spark to the DUT actuates the discharge ESD Simulator a dev...

Страница 3: ...0 4 2 ESD Rating Tests TPD1E04U04DPY D1 D5 can be used for destructive electrostatic discharge ESD pass or fail ESD strikes Specifically they can be used for both IEC 61000 4 2 air and contact discharge tests The procedure in Section 3 1 1 ensures proper testing setup and method for both discharge tests Each IO has a Test Pad TP1 TP5 directly connected to it for striking ESD 3 1 1 Test Method and ...

Страница 4: ...the ESD protection diode shifts 0 1 V or leakage current increases by a factor of ten then the device is permanently damaged by ESD 3 2 Scattering Parameters A TPD1E04U04 D6 is configured with 2 SMA J1 and J2 connectors to allow 2 port analysis with a vector network analyzer Connect Port 1 to J1 and Port 2 to J2 This configuration allows for the following terminology in 2 port analysis S11 Return ...

Страница 5: ... the oscilloscope attenuation of the measured signal is required Here is a procedure for testing D3 1 Ground the EVM using the banana connector J3 2 Attach two 10X attenuators in series to the oscilloscope channel being used 3 Attach the 50 Ω shielded SMA cable between J2 and the attenuators 4 Set the scope attenuation factor to 100X 5 Set the oscilloscope to trigger on a positive edge for ESD and...

Страница 6: ...ated TPD1E04U04 Evaluation Module 4 Board Layout This section provides the TPD1E04U04EVM board layout TPD1E04U04EVM is a 4 layer board of FR408HR at 0 062 inch thickness Layers 2 3 and 4 are ground planes and not shown here Figure 3 TPD1E04U04EVM Top Layer and Silkscreen 5 Schematics Figure 4 TPD1E04U04EVM Schematic ...

Страница 7: ...Table 3 Bill of Materials Count RefDes Description Package Reference Part Number MFR 6 D1 D2 D3 D4 D5 D6 1 Channel ESD Protection Device for Super Speed up to 6 Gbps Interface DPY0002A DPY0002A TPD1E04U04DPY Texas Instruments 2 J1 J2 Connector TH End launch SMA 50 Ω Connector TH End launch SMA 142 0761 881 Johnson 1 J3 Standard Banana Jack Insulated Black 6092 6092 Keystone ...

Страница 8: ...esponsible for compliance with all legal regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failur...

Отзывы:

Похожие инструкции для TPD1E04U04