Operation

2.1

Quick Start List for Stand-Alone Operation

Operation

To use the TPA3200D1EVM stand-alone or when connecting it into existing circuits or equipment, follow
these steps. Connections to the EVM module can be made by inserting stripped wire into the plated
through holes on the J1, J2 headers and using banana plugs for the other connectors on the PCB.

2.1.1

Power Supply (Step 1)

1. Ensure that all external power sources are set to OFF.
2. Connect an additional external regulated power supply set to 5 V to the module VDD and GND pins on

the top side of the J2 header.

Note:

This supply should be turned ON before the VCC supply is turned ON.

3. Connect an external regulated power supply adjusted from 8 V–18 V to the module VCC (J4) and GND

(J3) banana jacks taking care to observe marked polarity.

2.1.2

Evaluation Module Preparations (Step 2)

Inputs and Outputs

1. Ensure that all connections are made to the I

2

S inputs (SCLK, BCK, LRCK, DATA, and GND) on the

J1 header.

2. Connect a speaker across OUTP (J8) and OUTN (J7)
3. Install both gain jumpers GAIN0 (J5) and GAIN1 (J6). This sets the gain of the amplifier to the lowest

level, 12 dB.

Control Inputs

1. SHUTDOWN: This terminal is active low. A low on the device terminal (< 0.8 V) shuts down the

amplifier; a high (> 2 V) on the device terminal places the amplifier in the active state. Holding down
switch S1 places the amplifier in the SHUTDOWN state. Releasing S1 returns the amplifier to the
active state.

2. MUTE: This terminal is active high. A high on this terminal immediately terminates audio playback

through the speakers. However, the outputs are still active (they are switching). The outputs are not
disabled like the SHUTDOWN case. S3 on the EVM controls the state of the MUTE terminal. Switching
the left side of S3 to 1 turns Mute on. Switching S3 to the 0 position turns Mute off.

3. FORMAT: This terminal selects between two possible digital data input formats. S2 on the EVM

controls the data format. Switching the right side of S2 to 0 selects the 16-24 bit, I

2

S format. Switching

the right side of S2 to 1 selects the 16-bit right-justified format.

4. LSEL/RSEL: A typical digital input data stream consists of 2 channels of data. However, this amplifier

is a mono, bridged-tied amplifier. Therefore, it is necessary to select which channel of data is sent to
the mono output. This terminal is used to select between the 2 channels, typically left/right data.
Switching the left side of S2 to the RSEL position selects right-channel data. Switching the left side of
S2 to the LSEL position selects left-channel data.

5. DEMP: This terminal is used to enable/disable the internal 44.1-kHz de-emphasis filter. S3 on the EVM

controls the functionality of this terminal. Switching the right side of S3 to the 0 position disables the
44.1-kHz de-emphasis. Switching the right side of S3 to the 1 position enables the 44.1-kHz
de-emphasis.

6. GAIN0/GAIN1: Together, these terminals control the back-end gain of the amplifier. Jumpers J5 and

J6 control these terminals. The position of these jumpers and resulting gain is shown in

Table 2

.

4

TPA3200D1 Audio Power Amplifier Evaluation Module

SLOU173B – June 2005 – Revised July 2005

Содержание TPA3200D1

Страница 1: ...ction 2 2 Operation 4 3 Schematic PCB Layers and Parts List 9 4 TPA3200D1 EVM Parts List 11 List of Figures 1 The TI TPA3200D1 Audio Power Amplifier EVM Top View 2 2 The TI TPA3200D1 Audio Power Ampli...

Страница 2: ...This section provides a top and bottom view of the EVM and the EVM board specifications Figure 1 The TI TPA3200D1 Audio Power Amplifier EVM Top View TPA3200D1 Audio Power Amplifier Evaluation Module...

Страница 3: ...EVM Specifications TPA3200D1 VCC 8 V to 18 V Supply voltage range VDD 4 5 V to 5 5 V ICC 3 A max Supply current IDD 40 mA max Continuous output power per channel PO 8 20 W VCC 18 V THD N 10 RL Minimum...

Страница 4: ...active high A high on this terminal immediately terminates audio playback through the speakers However the outputs are still active they are switching The outputs are not disabled like the SHUTDOWN ca...

Страница 5: ...rminal in the Control Input section A test point TP1 is provided to monitor this output Power Up 1 Verify correct voltage and input polarity and turn the external power supplies on The supplies should...

Страница 6: ...uation Platform 2 2 1 Evaluation Platform Preparations Step 1 Setup 1 Install the EVM into the DEM DAI DAC platform in the location at the center of the platform The header labeled J1 should be attach...

Страница 7: ...This terminal is active high A high on this terminal immediately terminates audio playback through the speakers However the outputs are still active they are switching The outputs are not disabled li...

Страница 8: ...put section A test point TP1 is provided to monitor this output Power Up 1 Verify correct voltage and input polarity and turn the external power supplies on The supplies should be sequenced such that...

Страница 9: ...20 GND J2 1 2 VDD J3 J7 OUTN J8 OUTP GND J4 VCC S2 A 120 kW 120 kW R3 R4 120 kW J5 J6 S1 C14 C4 1 F m 1 F m 1 F m C5 C7 0 22 F m 0 22 F m 22 F m R6 51 R C10 C8 C13 D1 D2 1 nF C12 1 nF L2 L1 Ferrite B...

Страница 10: ...A3200D1 EVM PCB Layers Schematic PCB Layers and Parts List Figure 5 TPA3200D1 EVM Top Layer Figure 6 TPA3200D1 EVM Bottom Layer TPA3200D1 Audio Power Amplifier Evaluation Module 10 SLOU173B June 2005...

Страница 11: ...D1 D2 SMA 4 Diode Inc B130 13 1A Vr 30V B130DITR ND Ferrite Bead 0 05 ohms Mouser L1 L2 DCR 70 ohms at 100MHz 1206 2 Fair rite 2512067007Y3 623 2512067007Y3 3A Resistor chip 120 kohm Digi Key R1 R4 06...

Страница 12: ...e performance or infringement of patents or services described herein Please read the EVM User s Guide and specifically the EVM Warnings and Restrictions notice in the EVM User s Guide prior to handli...

Страница 13: ...iness practice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product wou...

Отзывы: