Stand-Alone Connection Diagrams
2-7
Operation
2.4
Stand-Alone Connection Diagrams
The power supply range is 4.5 V to 5.5 V and isolated RO/MO+ and LO/MO–
lines for BTL operation are required.
Note that the shutdown signal applied to the EVM SHUTDOWN pin must be
able to supply enough current to overcome the pullup resistor on the module
(100 k
Ω
).
2.4.1
TPA0213 Mono EVMs Connected for Stereo BTL Output
Figure 2–4 shows two TPA0213 EVMs connected for stereo BTL operation.
Figure 2–4. TPA0213 Mono EVMs Connected for Stereo BTL Output
GND
RO/MO+
LO/MO–
SHUTDOWN
GND
C3
VDD
GND
GND
LIN
VDD
GND
GND
RIN
TPA0213 EVM Board
U1
+
TEXAS
INSTRUMENTS
2000
R4
R7
S1
R1
STEREO/MONO
C4
C5
R2
R8
C6
C1
C2
MIN
J3
J2
J1
R3
R6
R9
R5
SLOP266
SHUTDOWN
R13
R10
+
C8
C7
R12
R1
1
GND
RO/MO+
LO/MO–
SHUTDOWN
GND
C3
VDD
GND
GND
LIN
VDD
GND
GND
RIN
TPA0213 EVM Board
U1
+
TEXAS
INSTRUMENTS
2000
R4
R7
S1
R1
STEREO/MONO
C4
C5
R2
R8
C6
C1
C2
MIN
J3
J2
J1
R3
R6
R9
R5
SLOP266
SHUTDOWN
R13
R10
+
C8
C7
R12
R1
1
Right
Left
5 VDC
Audio
Input
(Left)
Audio
Input
(Right)
5 VDC
GND
Table 2–7. Typical TPA0213 EVM Jumper Settings
EVM
J1
J2
TPA0213
ON
OFF
Note:
ON = Shunt installed, OFF = Open