![Texas Instruments TMS570LC4357 Скачать руководство пользователя страница 2048](http://html1.mh-extra.com/html/texas-instruments/tms570lc4357/tms570lc4357_technical-reference-manual_10956072048.webp)
Event A
Qual
DCAL
DCAEVT1
DCAEVT2
Event
Triggering DCAEVT1.inter
DCAEVT2.inter
DCBEVT
1. soc
DCBEVT1.inter
DCBEVT
2. inter
DCAEVT1.sync
DCAEVT1.soc
DCBEVT1.sync
DCBH
Event B
Qual
DCBL
DCBEVT1
DCBEVT2
Event
Filtering
Blanking
Window
Counter
Capture
DCEVTFILT
D
C
T
R
I
P
S
E
L
TZ1
TZ2
TZ3
DCAH
Digital Compare Submodule
Time- Base
submodule
Trip- Zone
submodule
Event- Trigger
submodule
DCAEVT1.force
DCAEVT2.force
DCBEVT1.force
DCBEVT2.force
COMP
GPIO
MUX
Latch
Generate
SOC
Pulse
When
Input = 1
2-bit
Counter
Set
Clear
Clear CNT
Inc CNT
ETPS[SOCBCNT]
ETPS[SOCBPRD]
ETCLR[SOCB]
SOCB
ETFRC[SOCB]
ETSEL[SOCB]
000
001
010
011
100
101
111
110
DCBEVT1.soc
[A]
ETFLG[SOCB]
CTR=Zero
CTR=PRD
CTRU=CMPA
CTRD=CMPA
CTRU=CMPB
CTRD=CMPB
ETSEL[SOCBSEL]
ePWM Submodules
2048
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Enhanced Pulse Width Modulator (ePWM) Module
shows the operation of the event-trigger's start-of-conversion-B (SOCB) pulse generator. The
event-trigger's SOCB pulse generator operates the same way as the SOCA.
Figure 35-43. Event-Trigger SOCB Pulse Generator
A
The DCBEVT1.soc signals are signals generated by the Digital compare (DC) submodule, described in
35.2.9 Digital Compare (DC) Submodule
illustrates where the digital compare (DC) submodule signals interface to other submodules
in the ePWM system.
The digital compare (DC) submodule compares signals external to the ePWM module to directly generate
PWM events/actions which then feed to the event-trigger, trip-zone, and time-base submodules.
Additionally, blanking window functionality is supported to filter noise or unwanted pulses from the DC
event signals.
Figure 35-44. Digital-Compare Submodule High-Level Block Diagram