www.ti.com
6.6.11 PLL Controller Command Register (PLLCMD)
PLL Controller Register Map
The PLL controller command register (PLLCMD) is shown in
and described in
for
PLLC1 and PLLC2. PLLCMD is used to initiate a GO operation for SYSCLKn ratio change and/or phase
alignment.
Figure 6-13. PLL Controller Command Register (PLLCMD)
31
16
Reserved
R-0
R-0
15
1
0
Reserved
GOSET
R-0
R/W-0
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 6-14. PLL Controller Command Register (PLLCMD) Field Descriptions
Bit
Field
Value
Description
31-1
Reserved
0
Reserved
0
GOSET
GO operation command for SYSCLKn ratio change and/or phase alignment. Before setting this bit
to 1 to initiate a GO operation, check the GOSTAT bit in the PLLSTAT register to ensure all
previous GO operations have completed.
0
Clear bit. Write of 0 clears bit to 0.
1
Initiates GO operation. Write of 1 initiates GO operation. Once set, GOSET remains set but further
writes of 1 can initiate the GO operation.
SPRUFB3 – September 2007
PLL Controllers (PLLCs)
55