SDRAM Interface
9-34
9.4.6
Timing Requirements
Table 9–15 shows five SDRAM timing parameters that decouple the EMIF from
SDRAM speed limitations. Three of these parameters are programmable via
the EMIF SDRAM control register; the remaining two are assumed to be static
values. The three programmable values ensure that EMIF control of SDRAM
obeys these minimum timing requirements. Consult the SDRAM data sheet
for information on the parameters that are appropriate for your particular
SDRAM.
Table 9–15. TMS320C6201/C6202/C6701 SDRAM Timing Parameters
Parameter
Description
Value in CLKOUT2/
ECLKIN2 Cycles
t
RC
REFR command to ACTV, MRS, or subsequent REFR command
TRC + 1
t
RCD
ACTV command to READ or WRT command
TRCD + 1
t
RP
DCAB command to ACTV, MRS, or REFR command
TRP +1
t
RAS
ACTV command to DEAC to DCAB command
7
t
nEP
Overlap between read data and a DCAB command
2
† CLKOUT2 cycles apply to the ’C6201/C6202/C6701, and ECLKOUT cycles apply to the ’C6211/C6711.