SLOS289E − DECEMBER 1999 − REVISED SEPTEMBER 2006
4
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
electrical characteristics at recommend operating conditions, V
DD
= 3 V and 5 V (unless otherwise
noted)
dc performance
PARAMETER
TEST CONDITIONS
TA†
MIN
TYP
MAX
UNITS
VIO
Input offset voltage
VIC = VDD/2,
VO = VDD/2 ,
25
°
C
175
3500
V
VIO
Input offset voltage
VIC = VDD/2,
RL = 100
Ω
,
VO = VDD/2 ,
RS = 50
Ω
Full range
4000
µ
V
α
VIO
Offset voltage draft
RL = 100
Ω
,
RS = 50
Ω
25
°
C
3
µ
V/
°
C
CMRR
Common-mode rejection ratio
VDD = 3 V,
RS = 50
Ω
VIC = 0 to 2 V,
25
°
C
63
dB
CMRR
Common-mode rejection ratio
VDD = 5 V,
RS = 50
Ω
VIC = 0 to 4 V,
25
°
C
68
dB
RL=100
Ω
25
°
C
78
84
VDD = 3 V,
RL=100
Ω
Full range
67
VDD = 3 V,
VO(PP)=0 to 1V
RL=10 k
Ω
25
°
C
85
100
AVD
Large-signal differential voltage
VO(PP)=0 to 1V
RL=10 k
Ω
Full range
75
dB
AVD
Large-signal differential voltage
amplification
RL=100
Ω
25
°
C
88
94
dB
amplification
VDD = 5 V,
RL=100
Ω
Full range
75
VDD = 5 V,
VO(PP)=0 to 3V
RL=10 k
Ω
25
°
C
90
110
VO(PP)=0 to 3V
RL=10 k
Ω
Full range
85
† Full range is 0
°
C to 70
°
C for C suffix and − 40
°
C to 125
°
C for I suffix. If not specified, full range is −40
°
C to 125
°
C.
input characteristics
PARAMETER
TEST CONDITIONS
TA†
MIN
TYP
MAX
UNITS
25
°
C
0.3
25
IIO
Input offset current
VIC = VDD/2
TLV411xC
Full range
50
IIO
Input offset current
VIC = VDD/2
TLV411xI
Full range
250
pA
VO = VDD/2,
25
°
C
0.3
50
pA
IIB
Input bias current
VO = VDD/2,
RS = 50
Ω
TLV411xC
Full range
100
IIB
Input bias current
RS = 50
Ω
TLV411xI
Full range
500
ri(d)
Differential input resistance
25
°
C
1000
G
Ω
CIC
Common-mode input capacitance
f = 100 Hz
25
°
C
5
pF
† Full range is 0
°
C to 70
°
C for C suffix and − 40
°
C to 125
°
C for I suffix. If not specified, full range is −40
°
C to 125
°
C.