www.ti.com
4.8
Clocks Tab
4.8.1
Configuring the codec clocks and Fsref calculation
TLV320AIC3104EVM Software
Figure 10. Clocks Tab
The TLV320AIC3104 provides a phase-locked loop (PLL) that allows flexibility in the clock generation for
the ADC and DAC sample rates. The Clocks tab contains the controls that can be used to configure the
TLV320AIC3104 for operation with a wide range of master clocks. See the Audio Clock Generation
Processing figure in the
data sheet for further details of selecting the correct clock
settings.
For use with the PC software and the USB-MODEVM, the clock settings must be set a certain way. If the
settings are changed from the default settings which allow operation from the USB-MODEVM clock
reference, the EVM settings can be restored automatically by pushing the Load EVMS Clock Settings
button at the bottom of this tab. Note that changing any of the clock settings from the values loaded when
this button is pushed may result in the EVM not working properly with the PC software or USB interface. If
an external audio bus is used (audio not driven over the USB bus), then settings may be changed to any
valid combination. See
The codec clock source is chosen by the CODEC_CLK Source control. When this control is set to
CLKDIV_OUT, the PLL is not used; when set to PLLDIV_OUT, the PLL is used to generate the clocks.
Note:
Per the
data sheet, the codec should be configured to allow the value of
Fsref to fall between the values of 39 kHz to 53 kHz.
SLAU218 – August 2007
TLV320AIC3104EVM and TLV320AIC3104EVM-PDK
17