4.8
AGC Tab
TLV320AIC3007EVM Software
www.ti.com
Figure 11. AGC Tab
The AGC tab (see
Figure 11
) consists of two identical sets of controls, one for the left channel and the
other for the right channel. The AGC function is described in the
TLV320AIC3007
data sheet.
The AGC can be enabled for each channel using the
Enable AGC
button.
Target
gain,
Attack
time in
milliseconds,
Decay
time in milliseconds, and the
Maximum PGA Gain Allowed
can all be set,
respectively, using the four corresponding knobs in each channel.
The TLV320AIC3007 allows for the Attack and Decay times of the AGC to be setup in two different
modes, standard and advanced. The
Left/Right AGC Settings
button determines the mode selection.
The
Standard
mode provides several preset times that can be selected by adjustments made to the
Attack
and
Decay
knobs. If finer control over the times is required, then the
Advanced
mode is selected to
change to the settings. When the
Advanced
mode is enabled, two tabs appear that allow separate,
advanced control of the Attack and Delay times of the AGC (see
Figure 12
and
Figure 13
). These options
allow selection of the base time as well as a multiplier to achieve the actual times shown in the
corresponding text box. The
Use advanced settings?
button must be enabled to program the registers
with the correct values selected via the pulldown options for base time and multiplier.
18
TLV320AIC3007EVM-K
SLAU286 – June 2009
Submit Documentation Feedback