background image

www.ti.com

4

4

EVM Use Restrictions and Warnings:

4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT

LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.

4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling

or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.

4.3

Safety-Related Warnings and Restrictions:

4.3.1

User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.

4.3.2

EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.

4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,

state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.

5.

Accuracy of Information:

To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate

as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.

6.

Disclaimers:

6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT

LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.

6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE

CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.

7.

USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS.

USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS

LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.

Содержание TLC6A598

Страница 1: ...BOM 12 List of Figures Figure 1 1 TLC6A598EVM Kit 2 Figure 2 1 TLC6A598EVM Test Bench Setup 4 Figure 2 2 USB2ANY Explorer 5 Figure 2 3 GPIO and SPI Selection 6 Figure 2 4 GPIO3 Configuration 7 Figure...

Страница 2: ...ircuit The TLC6A598EVM provides an eight channel relays control example solution It is designed to operate with two supply power rails one power rail for the TLC6A598 and another power rail for the re...

Страница 3: ...Typ Max Unit Input voltage range VCC 3 5 5 V Input voltage range VDD 24 V Relay G5NB 1A E D24 8 3 mA www ti com Introduction SLIU023 JUNE 2021 Submit Document Feedback TLC6A598 Power Logic 8 Bit Shif...

Страница 4: ...and install the USB2ANY Explorer Software on the computer Figure 2 1 shows the test bench setup for the evaluation of the TLC6A598EVM board 24V DC 5V DC USB Cable Edge cable PC Figure 2 1 TLC6A598EVM...

Страница 5: ...he USB2ANY Explorer Software and the software will show as Figure 2 2 Figure 2 2 USB2ANY Explorer Click the Select Interface button and choose the GPIO and SPI as Figure 2 3 and click the Close button...

Страница 6: ...PIO3 as Figure 2 4 If you cannot see the GPIO button please adjust the display scale of the PC to 100 Test Setup www ti com 6 TLC6A598 Power Logic 8 Bit Shift Register Evaluation Module SLIU023 JUNE 2...

Страница 7: ...k the SPI button and configure the SPI interface as Figure 2 5 www ti com Test Setup SLIU023 JUNE 2021 Submit Document Feedback TLC6A598 Power Logic 8 Bit Shift Register Evaluation Module 7 Copyright...

Страница 8: ...ate command window write FF and click Write Read button as Figure 2 6 Test Setup www ti com 8 TLC6A598 Power Logic 8 Bit Shift Register Evaluation Module SLIU023 JUNE 2021 Submit Document Feedback Cop...

Страница 9: ...ight Green LEDs D1 to D8 will turn on accordingly Please refer to the TLC6A598 data sheet for additional functional tests www ti com Test Setup SLIU023 JUNE 2021 Submit Document Feedback TLC6A598 Powe...

Страница 10: ...d in this section 3 1 Layout Figure 3 1 and Figure 3 2 demonstrate the TLC6A598EVM layout images Figure 3 1 TLC6A598EVM Top Layer Design Files www ti com 10 TLC6A598 Power Logic 8 Bit Shift Register E...

Страница 11: ...r 3 2 Schematic Figure 3 3 shows the TLC6A598EVM schematic www ti com Design Files SLIU023 JUNE 2021 Submit Document Feedback TLC6A598 Power Logic 8 Bit Shift Register Evaluation Module 11 Copyright 2...

Страница 12: ...2 10k R4 10k R6 10k R8 100nF 50V C3 10k R9 100nF 50V C4 10k R10 100nF 50V C1 10k R11 100nF 50V C2 10k R12 100nF 50V C8 10k R25 100nF 50V C9 10k R26 100nF 50V C10 10k R27 100nF 50V C11 10k R28 10k R18...

Страница 13: ...rade 0 0603 CRCW060310K0JNEA Vishay Dale TP1 TP2 TP3 TP4 TP5 5 Terminal Turret TH Double 1502 2 Keystone U1 1 50V 350mA 8ch Relay LED Driver TLC6A598 TI Will Provide Later C1 C2 C3 C4 C8 C9 C10 C11 0...

Страница 14: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 15: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 16: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 17: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 18: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 19: ...are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and...

Отзывы: