Micro-reader Module
25 July 1996
6.2 Micro-reader to PC
Successful Read of RO
Byte
Content (hex) Comment
Description
0
01
Start Mark
1
09
Length
9 bytes follow excluding BCC
2
0C
Status
Valid RO, Startbyte detected, DBCC O.K.
3
6A
Data Field (1)
Identification Data (LSByte)
4
58
Data Field (2)
Identification Data
5
4C
- : -
- : -
6
00
- : -
- : -
7
00
- : -
- : -
8
00
- : -
- : -
9
00
Data Field (7)
Identification Data
10
00
Data Field (8)
Identification Data (MSByte)
11
7B
BCC
BCC over previous bytes excluding Start Mark
Successful Program Page 2 of MPT
Byte
Content (hex) Comment
Description
0
01
Start Mark
1
0A
Length
10 bytes follow excluding BCC
2
1E
Status
Valid MPT, Startbyte detected, DBCC O.K., FBCC O.K.
3
47
Data Field (1)
New Identification Data (LSByte)
4
C6
Data Field (2)
New Identification Data
5
2D
- : -
- : -
6
00
- : -
- : -
7
00
- : -
- : -
8
00
- : -
- : -
9
00
Data Field (7)
New Identification Data
10
00
Data Field (8)
New Identification Data (MSByte)
11
09
Data Field (9)
Read Address specifying successful progr. of page 2
12
B1
BCC
BCC over previous bytes excluding Start Mark
No Read
Byte
Content (hex) Comment
Description
0
01
Start Mark
1
01
Length
One byte follows excluding BCC
2
03
Status
Other, no Startbyte, DBCC not O.K., FBCC not O.K.
3
02
BCC
BCC over previous bytes excluding Start Mark